User Manual

10
Owner’s Manual
Controls and Functions
r WORD CLOCK select key
Selects the word clock source of the RSio64-D.
WORD CLOCK [WCLK IN] indicator
WORD CLOCK [SLOT1 1/2] indicator
WORD CLOCK [DANTE] indicator
These indicate the status of the RSio64-D’s word clock
source.
*1 When this is flashing, the unit uses the Dante word clock to
operate and perform input/output.
*2 In order to use MY8-AEB, set AE RSVD switch to the
RSVD position.
*3 If you want to change the frequency of the Dante word
clock, use Dante Controller.
t ROUTING [PATTERN] rotary switch
This selects the RSio64-D’s internal audio routing
pattern from seven preset patterns and one user
pattern. Setting the rotary switch to 1–7 selects preset
routing patterns 1–7, and setting it to 0 selects the user
routing pattern.
NOTE
The routing pattern does not change if you select 8–F.
y SETUP [UNIT ID] rotary switch
Specifies an ID that identifies this device on the Dante
network. If there are multiple Dante-compatible
devices from Yamaha that require an ID setting
connected to the same network, set a different ID for
each device.
u Device setting DIP switches
These switches specify startup settings for the device.
Details are given below.
The switch illustrations indicate the setting state as
follows.
•Switch 1 (UNIT ID)
This switch setting determines whether the [UNIT ID]
setting will range from hexadecimal 00 to 0F or from 10
to 1F.
Switch 2/Switch 3 (IP SETTING)
These specify the method of setting the IP address used
when communicating with an external device such as R
Remote V4. When connecting the RSio64-D to a
computer for the first time immediately after purchase,
set this to something other than STATIC IP (MANUAL).
If you want to set this to STATIC IP (MANUAL), first
specify the IP address from R Remote V4 and then
switch this setting to STATIC IP (MANUAL).
WCLK IN
This is lit if the RSio64-D is using the word
clock that is being input from the rear panel
[WORD CLOCK IN] connector. This flashes if
there is no valid word clock input
*1
.
SLOT1 1/2
This is lit if the channel 1/2 word clock of slot 1
is being used. This flashes if there is no valid
word clock input
*1
. The channel 7/8 word clock
is used when using the MY8-AEB
*2
. If the
SRC on the MY8-AE96S is in use, you will be
unable to use the input signal as word clock.
DANTE
This is lit if the Dante network’s word clock
*3
is being used. (If no valid Dante signal is being
input, the clock generated by the internal
Dante module is used.)
Making the setting
You can select the routing pattern even when the
power is on. Your selection is applied three seconds
after you switch the routing pattern.
Making the setting
Turn off the power before you change the setting of
this rotary switch. The setting is applied the next
time you turn the power on. If you change the
setting while the power is on, the changed setting is
not applied until the power is turned off and on
again.
Making the setting
Turn off the power before you change these DIP
switch settings. The setting is applied the next time
you turn the power on. If you change the setting
while the power is on, the changed setting is not
applied until the power is turned off and on again.
(This note does not apply to switch 6.)
Switch State
Switch is in the upward (OFF) position.
Switch is in the downward (ON) position.
Switch Setting Description
UNIT ID =
00-0F
The UNIT ID setting range is 00
to 0F.
UNIT ID =
10-1F
The UNIT ID setting range is 10
to 1F.
Switch Setting Description
AUTO IP
The Dante network automati-
cally specifies the IP address as
169.254.XX.XX.
DHCP
The IP address assigned from
the DHCP server is used.
STATIC IP
(AUTO)
The IP address is specified as
192.168.0.xx (xx=UNIT ID).
STATIC IP
(MANUAL)
The IP address is specified from
an external device such as R
Remote V4.
ON
12345678
UNIT ID
IP SETTING
SECONDARY PORT
START UP MODE
1
1
2
3
2
3
3
2
3
2