User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Scene memory
Reference Manual
89
2 CH RECALL SAFE field
Indicates the channels currently specified for the Recall Safe function.
3 SET BY SEL button
Enables you to use the [SEL] keys on the panel to select channels that will be affected by the Recall
Safe function. Turn this button on, and then press the [SEL] key for the channel to which you want
to apply Recall Safe. The on-screen fader of the corresponding channel will turn green (all
parameters for the channel will be affected by the Recall Safe function), or turn blue (some
parameters for the channel will be affected by the Recall Safe function). Press the same [SEL] key
once again to de-select the channel.
4 GLOBAL RECALL SAFE field
Indicates the state of Recall Safe settings that are not made in units of channels, and the Recall Safe
settings for racks. Press this field to open the GLOBAL RECALL SAFE popup window.
5 Channel select button
Selects the channel for which you want to set the Recall Safe function.
NOTE
Switching channels using this button will not affect the channel selection on the top panel.
6 Selected channel display
This area indicates the icon, number, color, and name of the currently-selected channel.
7 APPLY TO ALL INPUT button (input channels only)
Turn on this button to apply the Recall Safe parameter selection for one input channel to all other
input channels.
This can be convenient if you want to apply Recall Safe to the same parameters for all input
channels.
8 APPLY TO ALL OUTPUT button (output channels only)
Turn on this button to apply Recall Safe parameter selection for one output channel to all other
output channels.
This can be convenient if you want to apply Recall Safe to the same parameters for all output
channels.
9 SAFE PARAMETER SELECT field (excluding DCA groups)
Selects Recall Safe parameters for the selected channel.
The button indication varies depending on the channel type, as follows:
• Input channel
NOTE
ST IN channels do not feature INSERT, INSERT PATCH, or DIRECT OUT button.
• MIX channel
• MATRIX channel
• STEREO channel
• MONO channel
If Recall Safe is turned on for global parameters, the safe parameter select buttons of the selected
channel will light green, as follows.
In this illustration, the items that are lit green indicate that the INPUT PATCH, INSERT PATCH,
and DIRECT OUT parameters have been set to Safe by the INPUT PATCH Global parameter
settings.
In the same way, turning on the Global parameters INPUT NAME, OUTPUT PATCH, OUTPUT
NAME , and HA will cause the corresponding safe parameters of each channel to light green.
All parameters are affected by Recall Safe on these channels.
Some parameters are affected by Recall Safe on these channels.
Recall Safe has been canceled on these channels.