6 DIP Switches
These switches enable you to specify the settings
related to the startup operation of the unit.
Set the DIP switches while the power to the unit is
turned OFF. Otherwise, the setting will not be
effective.
Refer to the following for details.
The switch illustrations indicate the setting state as
follows.
Switch 1 (UNIT ID)
This switch setting determines whether the
hexadecimal setting of the [UNIT ID] rotary switch
will range from 0 to F or from 10 to 1F.
Switches 2 and 3 (IP SELECT MODE)
These specify the method of setting the IP address
used when communicating with an external device
such as R Remote. When connecting the R series to a
computer for the first time immediately after
purchase, set this to something other than STATIC IP
(MANUAL). If you want to set this to STATIC IP
(MANUAL), first specify the IP address from R
Remote and then switch this setting to STATIC IP
(MANUAL).
Switch 4 (SECONDARY PORT)
This switch setting determines whether the rear-panel
[SECONDARY] connector will be used for a daisy
chain or redundant network.
With the [DAISY CHAIN] setting, you can connect
multiple Dante-enabled network devices in a daisy
chain without using a network switch. Refer to “Daisy
Chain Network” in the “About Connections” section
(see page 13) for more information about daisy chain
connections.
With the [REDUNDANT] setting, the [PRIMARY]
connector will be used for primary connections, and
the [SECONDARY] connector will be used for
secondary (backup) connections. If the unit is unable
to transmit signals through the [PRIMARY]
connector for some reason (e.g., due to damage or
accidental removal of the cable, or a failed network
switch), the [SECONDARY] connector will
automatically take over communications and
functions on the redundant network. Refer to “About
Redundant Networks” in the “About Connections
section (see page 13) for more information on
redundant networks.
Switch Status
Represent a status with switch toggled up.
Represent a status with switch toggled down.
Switch Setting Description
UNIT ID
ranging from
0 to F
The setting range of the
[UNIT ID] rotary switch is
from 0 to F.
UNIT ID
ranging from
10 to 1F
The setting range of the
[UNIT ID] rotary switch is
from 10 to 1F.
Switch Setting Description
AUTO IP Dante networks will
automatically assign the IP
address.
DHCP The IP address assigned
by the DHCP server will be
used.
STATIC IP
(AUTO)
The IP address will be set
to 192.168.0.xx (xx=UNIT
ID).
STATIC IP
(MANUAL)
The IP address is specified
from an external device
such as R Remote.
2
3
2 3
2
3
2
3
Switch Setting Description
DAISY CHAIN The [SECONDARY]
connector is used for a
daisy chain connection. A
signal at the [PRIMARY]
connector will be
transmitted to the next
device in the chain as is.
REDUNDANT The [SECONDARY]
connector is used for a
redundant network. It will
function as backup
connection, independent of
the network to which the
[PRIMARY] connector is
connected.