User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
MIDI
V5.8 Reference Manual
200
2 DESTINATION field
Enables you to select the scene or library item to recall. If EFFECT or PREMIUM RACK is
selected in the TYPE field, the rack number will be shown. If SCENE is selected, this will
indicate - - -, and is not used.
3 LIBRARY NUMBER/LIBRARY TITLE field
Enables you to choose the library that you want to recall.
If SCENE or EFFECT is selected in the TYPE field, the LIBRARY TITLE is shown. If PREMIUM
RACK is selected, the LIBRARY NUMBER is shown.
4 OK button
Confirms the settings and closes the window.
Using control changes to control parameters
You can use MIDI Control Change messages to control specified events (fader/knob
operations, [ON] key on/off operations etc.) on the CL series console. This capability can be
used to record fader and key operations on a MIDI sequencer or other external device, and
play back this data later.
You can use Control Changes to control events in either of the following two ways.
Using Control Changes
This method uses typical Control Changes (control numbers 1-31, 33-95, 102-119). You can
freely assign an event to each control number.
Using NRPN (Non Registered Parameter Number)
This method uses a special type of Control Change messages called NRPN.
NRPN uses Control Change numbers 99 and 98 to specify the MSB (Most Significant Byte)
and LSB (Least Significant Byte) of the parameter number, and subsequently-transmitted
Control Change messages of Control Change number 6 (or 6 and 38) to specify the value of
that parameter.
The event assigned to each combination of MSB and LSB is pre-defined, and cannot be
changed.
NOTE
For details on the events assigned to NRPN messages, refer to the data list at the end of this
manual.
NOTE
Assignments to control numbers are maintained as settings for the entire system, rather than for
individual scenes.
STEP
1. Connect the CL series console to an external device.
2. As described in “Basic MIDI settings” (page 195), select the ports and MIDI channels
that will be used to transmit/receive control changes.
3. Press the CONTROL CHANGE tab in the MIDI/GPI screen.
4. Switch Control Change transmission/reception on or off, select transmission/
reception mode, and set echo output.
5. To change the event assignment for each control number, press the desired event
in the list and select an event type and the recall target.
MIDI/GPI screen
(CONTROL CHANGE page)