User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Other functions
V5.8 Reference Manual
284
Other functions
This chapter explains various functions of CL series consoles that are not covered in other
chapters.
Initializing the unit to factory default settings
If an error occurs in the CL console internal memory, or if you forget the password and cannot
operate the unit, you can use the following procedure to initialize the internal memory.
There are two types of initialization of the internal memory as shown below.
INITIALIZE ALL MEMORIES
The entire memory, including scene memories and libraries, will be returned to factory default
settings.
INITIALIZE CURRENT MEMORIES
The contents of memory - except for scene memories and libraries - will be returned to its
factory default settings.
CAUTION
The entire memory will be deleted if you initialize the internal memory! Proceed with the operation
only if you are very sure you want to delete the entire memory.
However, the settings in DANTE SETUP will not be initialized. To initialize these settings, refer to
“Initializing the console settings and Dante audio network settings” (page 288).
NOTE
• Do not press any buttons until initialization is complete.
• Once initialization is complete, you can continue operation by selecting a different menu instead
of pressing the EXIT button.
Adjusting the detection point of the touch screen
(Calibration function)
Follow the steps below to correctly align the positions of the LCD display and the touch
screen.
NOTE
• If you are unable to start calibration by pressing the TOUCH SCREEN CALIBRATION button, you
can use the SCENE MEMORY [INC]/[DEC] keys to select TOUCH SCREEN CALIBRATION, and
then press the [STORE] key to start.
• To set the detection points accurately, press the cross-shaped cursor from the position and
posture in which you normally operate the unit.
• Once initialization is complete, you can continue operation by selecting a different menu instead
of pressing the EXIT button.
STEP
1. While holding down the SCENE MEMORY [STORE] key on the panel, turn on the
power to the CL unit.
2. On the startup menu screen, select the initialization method.
3. Press the INITIALIZE button in the dialog box to confirm initialization.
4. Press the OK button in the confirmation dialog box to start initialization.
5. A message indicates that the initialization process is complete. Press the EXIT button
on the startup menu screen.
Startup menu screen
STEP
1. While holding down the SCENE MEMORY [STORE] key on the panel, turn on the
power to the CL unit.
2. On the startup menu screen, press the TOUCH SCREEN CALIBRATION button.
3. Press the START button in the TOUCH SCREEN CALIBRATION MODE screen.
4. Press the OK button in the confirmation dialog box to start calibration.
5. A cross-shaped cursor will appear in the screen (a total of three times). Press each
location at which it appears.
6. Press the EXIT button on the startup menu screen to start up the CL unit in normal
operating mode.
Startup menu screen TOUCH SCREEN CALIBRATION
MODE screen