User Manual

Yamaha Commercial Audio
Dante-MY16-AUD HA Remote Control Guide
10 www.yamahaproaudio.com
If the R series in NATIVE mode and that in AD8HR mode coexist within one
network, a duplicated UNIT ID between the different modes is acceptable (with
the CL and R series firmware v1.5 or later).
SECONDARY PORT
Flip the DIP switch 4 up for daisy-chain connection, or down for redundant
connection (star connection with switches).
REMOTE
Establish the AD8HR mode (flip DIP switch 5 down). The mixer will recognize
the R series as AD8HR (multiple units).
In this case, however, functions specific to the CL series, such as the Gain
Compensation function, are disabled. In the system where the CL series and
other mixers coexist, to control the HA from only the CL series, you can
operate it as in NATIVE mode.
START UP MODE
Regardless of the DIP switch setting, the R series units in AD8HR mode
always operate in RESUME mode, in which the units start up using their HA
settings assigned prior to the most recent power-off.
Note:
Therefore, if you wish to erase any previous unwanted HA settings, first set DIP
switches 5, 6, 7, 8 up and power-on the R series for at least 30 seconds. Then
turn off the power, and set DIP switch 5 down for AD8HR mode before turning the
power on again.