User Manual
Table Of Contents
- Cover
- Introduction
- Setup workflow
- Example 1) Basic MTX3 system example (analog connections)
- Example 2) High audio quality system with XMV and YDIF connections (digital connections)
- Example 3) Using cascade mode to add MTX input channels (analog connection)
- Using the Device Configuration Wizard to create your device setup
- Making preliminary settings in MTX-MRX Editor
- Connecting the equipment
- Powering-on the MTX
- Powering-on the amp
- Setting the MCP1’s UNIT ID
- Specifying the computer’s TCP/IP address
- Taking MTX-MRX Editor online
- Making XMV settings
- Verifying that the settings were applied
- Example 4) A system using Dante
- Using the Device Configuration Wizard to create your device setup
- Making preliminary settings in MTX-MRX Editor
- Dante settings between systems
- Connecting the equipment
- Powering-on the MTX
- Powering-on the amp
- Specifying the computer’s TCP/IP address
- Taking MTX-MRX Editor online
- Making XMV settings
- Verifying that the settings were applied
- Example 5) A system using the PGM1 for paging
- Using the Device Configuration Wizard to create your device setup
- Making preliminary settings in MTX-MRX Editor
- Connecting the equipment
- Power-on the PoE-equipped gigabit network switch
- Power-on equipment other than amps and powered speakers
- Power-on amps and powered speakers
- Specifying the computer’s TCP/IP address
- Taking MTX-MRX Editor online
- Making XMV settings
- Verifying that the settings were applied
- Q&A
- Uninstalling the software (Removing the application)
Example 2) High audio quality system with XMV and YDIF connections (digital connections)
MTX Setup Manual
32
4.
Set the [UNIT ID] rotary switch and DIP switch of the MTX and XMV.
You will set the computer’s IP address after completing the wizard, in “Specifying the computer’s TCP/IP address.”
If the MTX and XMV are not nearby, you can set them during the step “Connecting the equipment.”
Make the following settings.
5.
When you have finished setting the [UNIT ID] rotary switch and DIP switch of the MTX and
the XMV, click [Next>].
MTX3
UNIT ID = 01
[UNIT ID] rotary switch = 1
DIP switches are all OFF (upward)
XMV
UNIT ID = 1A
[UNIT ID] rotary switch = A
DIP switch 1 is ON (downward), others are OFF (upward)
NOTE
Use the DIP switch to specify the upper digit of the UNIT ID, and use the [UNIT ID] rotary switch to specify the lower digit. For
details, refer to the owner’s manual of each unit.
UNIT ID = 1 A
Lower digit: specify using the rotary switch
Upper digit: specify using DIP switch 1–3