User Manual

MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V1.3.0
70
7. Parameter List
Model Access ID
Category Prarameter Name MIN MAX unit Remarks
MTX3
MTX5-D
MemNo
(Memory
Number)
UniqueId
ElmNo
(Element
Number)
Xpos
(X Position)
Ypos
(Y Position)
PrmNo
(Parameter
Number)
IndexNo
(Index
Number)
o
512 60003 0 0-7
(ZONE1-8)
0 0 0 ZONE MATRIX
OUTPUT
MASTER
DCA Mute
8(16) Channel
On On OFF ON - 0:OFF
1:ON
o
0-15
(ZONE1-16)
o
1 0-7
(ZONE1-8)
0-7
(A-H)
0
DCAAssign
AssignOn
OFF ON - 0:OFF
1:ON
o
0-15
(ZONE1-16)
o 2 0 0-7
(A-H)
0 Group
Master
MuteOn OFF ON - 0:OFF
1:ON
o
o o
70001 0 0-7
(ZONE1-8)
0 0 0
ChannelName
Channel
Name 8(16)
Channel
ChName
Name Charactor (UTF-8)
48byte
-
o
70005 0-7
(ZONE9-16)
o
20016 1 0 0-7
(OUT1-8)
0 0 ROUTER ROUTOR Bus Out
Router 24(32)
Input x 8(16)
Output
In Patch NONE YDIF
OUT 16
- * See
"9.ROUTER" in
"7. Parameter
Values"
o
20023
0-15
(OUT1-16)
o
20017 0 0-7
(OUT1-8)
0 0 0
OUTPUT
CHANNEL
OUTPUT
CHANNEL
LEVEL
Fader 8(16)
Channel
Fader Level -∞ 10.00 dB dB x 100
ex.-73.60dB x 100
= -7360
"setr" command is
available for this
parameter
o
20024 0-15
(OUT1-16)
o
20017 1 0-7
(OUT1-8)
On On OFF ON - 0:OFF
1:ON
o
20024 0-15
(OUT1-16)
o o
70002 0 0-7
(OUT1-8)
0 0 0
ChannelName
Channel
Name 8(16)
Channel
ChName
Name Charactor (UTF-8)
48byte
-
o
70006 0-7
(OUT9-16)
o
20018 0 0-7
(OUT1-8)
0 0 0 DELAY Delay 8(16)
Channel
Delay On OFF ON - 0:OFF
1:ON
o
20025 0-15
(OUT1-16)
o
20018 0 0-7
(OUT1-8)
1
DelayTime
0.00 1000.00 ms ms x 100
ex. 102.80ms x
100 = 10280
o
20025 0-15
(OUT1-16)
o
20019 0 0-7
(OUT1-8)
0-3
(0:Band A
1:Band B
2:Band C
3:Band D)
0 0 4BAND EQ PEQ 8(16)
Channel 4
Band
PEQ Q(*) 63.0 0.1 - * See "2.3BAND
EQ / 4 BAND EQ"
in "7. Parameter
Values"
o
20026 0-15
(OUT1-16)
o
20019 0 0-7
(OUT1-8)
1 0
Frequency
20.0(*) 20.0k Hz *(100 : Other than
Band A)
Hz x 1000
ex. 1000Hz x
1000 = 1000000
o
20026 0-15
(OUT1-16)
o
20019 0 0-7
(OUT1-8)
2 0 Gain(*) -18.0 18.0 dB * Not adjustable
for HPF/LPF
dB x 10
ex. -14.5dB x 10
= -145
o
20026 0-15
(OUT1-16)
o
20019 0 0-7
(OUT1-8)
3 0 Bypass OFF ON - 0:OFF
1:ON
o
20026 0-15
(OUT1-16)
o
20019 0 0-7
(OUT1-8)
0, 3
(0:Band A
3:Band D)
4 0 Type PEQ LPF - * See "2.3BAND
EQ / 4 BAND EQ"
in "7. Parameter
Values"
o
20026 0-15
(OUT1-16)
o
20019 1 0-7
(OUT1-8)
0 0 0 Property PEQOn OFF ON - 0:ON
1:OFF
o
20026 0-15
(OUT1-16)