User Manual
Table Of Contents
- Notice regarding data copyright
- Notice regarding the content of this user guide
- Contents
- Chapter 1. An overview of MTX-MRX Editor
- An audio system control network
- Terms used in this user guide
- Data handled by MTX-MRX Editor
- Connection requirements for an MTX/MRX system
- MTX/MRX system configuration examples
- What are YDIF connections? (Cascade mode and Distribution mode)
- What are Dante connections? (Daisy-chain connection and Star connection)
- Patching
- Workflow
- About the screens
- Moving between screens
- Chapter 2. Menu bar and tool buttons
- Chapter 3. Project screen
- Chapter 4. System screen
- Chapter 5. Online and Synchronization
- Chapter 6. Presets
- Chapter 7. Dialog boxes/Software applications
- “Startup” dialog box
- “Network Setup” dialog box
- “Device Information” dialog box
- “Match Device by IP Address” dialog box
- “MTX Configuration” dialog box
- “Dante Information” dialog box
- “Word Clock” dialog box
- “Clock” dialog box
- “Daylight Saving Time” dialog box
- “Scheduler” dialog box
- “Remote Control” dialog box
- “External Events” dialog box
- “Digital Control Panel” dialog box
- “Wireless DCP” dialog box
- “MCP1” dialog box
- “PIN Setup” dialog box
- “Label” dialog box
- “Re-size Image” dialog box
- “PGM1/PGX1” dialog box
- “PGM1 Label Creator” application
- “GPI” dialog box
- “GPI Calibration” dialog box
- “Security Settings” dialog box
- “Project Information” dialog box
- “Configuration Diagram” dialog box
- “Get Log” dialog box
- “Sampling Rate Converter” dialog box
- “Input Source/Redundant” dialog box
- Appendix
List of settings in “Settings” dialog boxes Appendix
MTX-MRX Editor User Guide
254
❍ Low Active
Use this if you selected [ON] or [Send ON] as the [FUNCTION].
The function will turn off when the input voltage to GPI IN rises above the center
voltage, and will turn on when it falls below the center voltage.
If you’ve selected [Input Ch Mute Group] or [Zone Out Mute Group] as the parameter
type, mute on/off will be switched.
❍ Rising Edge
Use this if you selected [ON]/[Send ON]/[SD Play]/[Preset Recall] as the
[FUNCTION].
The parameter will alternately turn on/off or play/stop etc. when the input voltage
to GPI IN changes from below the center voltage to above it.
[Preset Recall] will recall the specified preset when the input voltage changes from
below the center voltage to above it.
❍ Falling Edge
Use this if you selected [ON]/[Send ON]/[SD Play]/[Preset Recall] as the
[FUNCTION].
The parameter will alternately turn on/off or play/stop etc. when the input voltage
to GPI IN changes from above the center voltage to below it.
[Preset Recall] will recall the specified preset when the input voltage changes from
below the center voltage to above it.
● If [FUNCTION] is [No Assign]
With this setting, no function will be operated by the signal that is input from the [GPI
IN] connector. [DEVICE], [PARAMETER1/2], and [INPUT TYPE] will be
unavailable.
GPI IN input
voltage max.
GPI IN input
voltage min.
ON
ON
OFF OFF
OFF OFF
Center voltage
NOTE
GPI IN input
voltage max.
GPI IN input
voltage min.
Center
voltage
ON/play OFF/stop ON/play
NOTE
GPI IN input
voltage max.
GPI IN input
voltage min.
Center
voltage
ON/play OFF/stop ON/play