User Manual
Table Of Contents
- Cover
- What is Amp Editor?
- Special Notices
- Contents
- Preparing for operation
- An overview of Amp Editor
- Setup
- Basic operations in Amp Editor
- Main panel window
- Objects in the window and their function
- Menus in the main panel window
- Preferences
- Event Log
- Device Information
- Scene Manager
- Alert Setup
- Word Clock (TXn only)
- Speaker Processor Library Manager (TXn only)
- Clock
- Language (TXn only)
- GPI (ACD1 only)
- Utility
- IP Address
- IP Control Port No.
- Firmware Update (Updating the internal firmware)
- Scene Link Manager (for devices other than XMV)
- Network Setup
- Synchronization (Synchronization with devices)
- Custom Control Panel Manager
- System View Creator
- Speaker Processor Library Converter
- Tree View window
- Detail View window
- Device Properties window
- Signal Path View window (TXn only)
- Component editor (TXn only)
- Custom control panels
- Appendix
Chapter 5 Main panel window
Amp Editor Owner’s Manual
74
GPI OUT
For each port, you can specify a device’s parameter whose state will be output from GPI OUT. The column at
the far left indicates the port number.
Function
Specify the function whose state will be output from GPI OUT. You can select one of seven functions: [No
Assign], [Scene Recall], [Mute], [Standby/On], [Parameter Value Edit], [Direct Parameter Value] and
[Alert]. The editable content of [Device], [Parameter], [Threshold], [Polarity], and [Output Type] will
change according to the function you select.
[No Assign]
No function will be assigned, and nothing will be output from GPI OUT. This is the default value.
You can use [Output Type] to specify only the polarity of the output signal during an alert occurrence.
The [Device], [Parameter], [Threshold], and [Polarity] fields are unavailable.
[Scene Recall]
The recall status of the specified scene will be output from GPI OUT. Use [Device] to select the appro-
priate amplifier. If you select “ALL,” all amplifiers connected to that device will be selected.
Use [Parameter] to specify the number of the scene whose recall status will be sent from GPI OUT.
[Threshold] and [Polarity] are unavailable. [Output type] specifies how the voltage to GPI OUT will be
output.
Output Type GPI OUT output
Closed will be output if the current scene is the same scene specified by [Parame-
ter], and Open will be output otherwise.
Open will be output if the current scene is the same scene specified by [Parameter],
and Closed will be output otherwise.
The output will briefly change (for 250 msec) from Open to Closed if the current
scene is the same scene specified by [Parameter].
The output will briefly change (for 250 msec) from Closed to Open if the current
scene is the same scene specified by [Parameter].