[GPI Lock]
The GPI Lock status will be output at the [GPI OUT] connector.
[Alert]
The command will be output at the [GPI OUT] connector when a specified alert occurs.
Output Type
Connection examples using the [GPI OUT] connector
[OUTPUT TYPE] allows the following settings.
Closed
Open
Pulse
Pulse Inv.
Closed
When the selected [Function] state occurs, the contact will be closed.
If [Parameter Value Edit] is selected, the contact will be closed when the specified threshold is exceeded.
If [Direct Parameter Value] is selected, the contact will be closed when the specified value is reached.
Press the [Active] button to close the contact.
Press the [InActive] button to open the contact.
Open
When the selected [Function] state occurs, the contact will be opened.
If [Parameter Value Edit] is selected, the contact will open when the specified threshold is exceeded.
If [Direct Parameter Value] is selected, the contact will open when the specified value is reached.
Press the [Active] button to open the contact.
Press the [InActive] button to close the contact.
Pulse
If the [Direction] is [Upward], the contact will change from closed to open for approximately 250 ms when
the selected [Function] state occurs.
If [Parameter Value Edit] is selected, the contact will change from open to closed for approximately 250
ms when the value exceeds the threshold.
If the [Direction] is [Downward], the contact will change from closed to open for approximately 250 ms
when the selected [Function] state is cleared.
If [Parameter Value Edit] is selected, the contact will change from open to closed for approximately 250
ms when the value falls below the threshold.
Press the [Active] button to open the contact for 250 ms.
The [InActive] button is disabled.