User Manual

How to read the indicators
-
18
-
Owner’s Manual
Tio1608-D2
Warnings
The indicators will light and/or flash as shown until the cause is resolved.
If the green [SYNC] is unlit, the unit’s clock is unconfirmed.
If the green indicator is flashing, the unit is the clock leader.
If the green indicator is lit, the unit is the clock follower and the clock is synchronized.
Information Message
The indicators will remain lit and/or flashing cyclically to report the status.
If the orange [SYNC] is unlit, the unit is operating normally.
If the green [SYNC] is unlit, the unit's clock is unconfirmed.
[SYNC] Description Possible Solution
Off Flashing
Clock settings are incorrect. Check the clock leader and sampling
frequency settings of the Tio1608-D2 and
Dante Controller.
Off Flashes 2 times
Unit not connected to Dante network. Make sure the cables are not damaged and
that they are connected properly.
Off Flashes 3 times
Cable wiring is wrong; cannot find other
Dante devices.
Check the wiring of the Ethernet cables.
[SYNC] Description Possible Solution
Lit or flashing Lit
Device that is not Gigabit Ethernet
compatible is connected.
To use Dante to send and receive digital
audio, make sure your devices are Gigabit
Ethernet compatible.
Lit or flashing Flashing
When using a redundancy network,
[SECONDARY] is sending/receiving audio.
Check the connections of the network
connected to the [PRIMARY].
Lit or flashing Flashes 2 times
When using a redundancy network, error
was detected on the [SECONDARY].
Check the connections of the network
connected to the [SECONDARY].
[SYNC] Description Possible Solution
Off Lit
Synchronizing on a Dante network. Please wait until started has completed or
until the unit has finished synchronization. It
may take up to 45 seconds for completion.
Waiting to receive setting data. If START UP MODE is set to REFRESH on
the Tio1608-D2 unit, the input/output will be
muted until the unit receives setting data after
it starts up.
Flashing Off
The unit is functioning correctly as the word
clock leader.
The unit is operating as the word clock
leader.
Lit Off
The unit is functioning correctly as the word
clock follower.
The unit is operating as the clock follower
and the clock is synchronized.