7. Parameter List
7.3. XMV Series
Model Access ID
Parameter Name MIN MAX unit Remarks
4ch 8ch
4ch D 8ch D
MemNo
(Memory
Number)
UniqueId
ElmNo
(Element
Number)
Xpos
(X Position)
Ypos
(Y Position)
PrmNo
(Parameter
Number)
IndexNo
(Index
Number)
o o 512 1 4 0 to 3 0 0 0
Signal
Processing
ATT *2 -99 0 dB Synchronized
with DigitalATT
o o 0 to 7
o o 0 to 3 0 1 0 Digital
ATT *2
-99 0 dB Synchronized
with ATT
o o 0 to 7
o o 0 to 3 0 2 0 Mute OFF ON - 0:OFF
1:ON
o o 0 to 7
o o 0 to 3 0 3 0 Polarity Normal Inverse - 0:Normal
1:Inverse
o o 0 to 7
o o o o
6 0 0 0 0 Power Standby Standby ON - 0:ON
1:Standby
o o o o
7 0 0 0 0 Utility
InputSelect
*1 *3
Analog Multiple - Switching input
source of all
channel.
0:Analog
1:Digital
2.Multiple
o
o o o
10 0 0 0 0
DigitalInput
Sensitivity
Type
0dB +17dB - 0: -20dBFS
1: -3dBFS
o o
11 0 to 3 0 0 0 ChUtility
Input
Select *3
Analog Digital - Switching input
source of by
channel.
0:Analog
1:Digital
o o
0 to 7 0 0 0
o o
2 0 0 to 3 0 0 0 Channel
Name
Channel
Name 4
Channel
ChName
Name Character (UTF-8)
48byte
- Notication only
o o
0 to 7 0 0 0 Channel
Name 8
Channel
*1 : Note
The XMV’s input sensitivity is -3dBFS (rated output at -3dBFS) when connected via digital (YDIF or Dante) and +4dBu (rated output
at +4dBu) when connected via analog.
Please set an appropriate level before switching input.
*2 : The ATT and DigitalATT parameters are always synchronized internally within an XMV amplier.
Controlling either one will provide the same result.
*3 : When "Utility/InputSelect" is changed to "Analog (or Digital)", "ChUtility/InputSelect" for all channels will be forcibly changed to
Analog (or Digital).
When "ChUtility/InputSelect" for all channels are set as "Analog (or Digital)" and a channel is changed to “Digital (or Analog)”,
"Utility/InputSelect" will be forcibly changed to "Multiple".
< XMV Block Diagram > e.g. XMV4280/XMV4140/XMV4280-D/XMV4140-D
In
Dante
Dante model only
PRIMARY
Out
ATT
INPUT
REDUNDANCY
YDIF
YDIF model only
DIGITAL INPUT
SENSITIVITY
Dante
Redundancy
INPUT
SOURCE
SELECT
HA
CH A, B, C, D
(E, F, G, H for XMV8xxx)
G
+
-
AD
-3dBFS
-20dBFS
SECONDARY
ATT
ATT
DigitalATT