User Manual

Table Of Contents
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.2.0 rev11
30
3. Command Specications
3.3.6. Meter control
2-17) Transmission request
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Option 3 Description
mtrstart MTX:mtr_MemNo/UniqueId/meter (interval) Requests that the specied meter data be transmitted.
Details: MemNo = See section 8, "Meter List."
UniqueId = See section 8, "Meter List."
(interval) = Minimum transmission interval (msec)
Response
Response string Description
OK mtrstart MTX:mtr_MemNo/UniqueId/meter Meter data transmission setting complete
Details: MemNo = See section 8, "Meter List."
UniqueId = See section 8, "Meter List."
Example: Command: mtrstart MTX:mtr_512/20020/meter 1000
Notication: OK mtrstart MTX:mtr_512/20020/meter
NOTIFY mtr MTX:mtr_512/20020/meter level 71 71 71 71 71 71 69 68
NOTIFY mtr MTX:mtr_512/20020/meter level 71 71 71 71 71 71 69 68
* The meter value is expressed using a 2-digit hexadecimal.
Meaning: Send the meter data of ch1 to 8 output levels at 1000 msec intervals.
A request for the ch1 to 8 output levels was received, so the data will be transmitted.
MRX7-D
Command Option 1 Option 2 Option 3 Description
mtrstart MTX:Index_IndexNo level (interval) Requests specied level meter data be
transmitted.
gr Requests specied Gain Reduction meter
data be transmitted.
hold Requests specied Hold meter data be
transmitted.
Details: IndexNo = Index number assigned in Remote Control Setup List
(interval) = Minimum transmission interval (msec)
Response
Response string Description
OK mtrstart MTX:Index_IndexNo level Level meter data transmission setting complete
OK mtrstart MTX:Index_IndexNo gr Gain Reduction meter data transmission setting complete
OK mtrstart MTX:Index_IndexNo hold Hold meter data transmission setting complete
Details: IndexNo = Index number assigned in Remote Control Setup List
Example: Command: mtrstart MTX:Index_2 level 1000
Notication: OK mtrstart MTX:Index_2 level
NOTIFY mtr MTX:Index_2 level 71 71 71 71 71 71 69 68
NOTIFY mtr MTX:Index_2 level 71 71 71 71 71 71 69 68
(V2.02 or earlier OK mtrstart MTX:Index_002 level
NOTIFY mtr MTX:Index_002 level 71 71 71 71 71 71 69 68
NOTIFY mtr MTX:Index_002 level 71 71 71 71 71 71 69 68)
* The meter value is expressed using a 2-digit hexadecimal.
Meaning: Send the meter data of ch1 to 8 which are assigned to Index 1 in Remote Control Setup List using
1000 msec intervals.
A request for Ch1 to 8 which are assigned to Index 1 in Remote control Setup List was received,
data will be transmitted.