MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.2.0 rev11
9
1. Setup
1.2. Conguring the Remote Controller
MTX3, MTX5-D and MRX7-D can be controlled from an external controller through the Ethernet (NETWORK) connector and RS-232C
(REMOTE) connector.
XMV, EXi8 and EXo8 can be controlled from an external controller through the Ethernet (NETWORK) connector.
The conguration on the remote controller side for each type of connection is shown below.
Ethernet (NETWORK connector) control
IP Address: Specify the IP address of the device you want to control.
IP Port No.: 49280
RS-232C (REMOTE connector) control
Bit Rate: The specied bit rate.
Data: 8 bits
Parity: none
Stop bit: 1 bit
Flow Control : none
RS-232C port pin assignment
Pin Name In/Out Pin Name In/Out
1 NC - 6 DSR In
2 RxD In 7 RTS Out
3 TxD Out 8 CTS In
4 DTR Out 9 NC -
5 GND -
* Pin 4 and Pin 6 are connected internally.
* Pin 7 and Pin 8 are connected internally.