User Manual

MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V1.0.3
16
3. Command Specications
3.3.4. Parameter query
2-10) Raw value parameter query
Command Option 1 Option 2 Option 3 Description
get MTX:mem_MemNo/UniqueId/ElmNo/Xpos/
Ypos/PrmNo/IndexNo
0 0 Raw value parameter query
request
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Xpos = See section 7, "Parameter Values."
Ypos = See section 7, "Parameter Values."
IndexNo = See section 7, "Parameter Values."
Response
Response string Description
OK get MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value)
Raw value parameter query response
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Xpos = See section 7, "Parameter Values."
Ypos = See section 7, "Parameter Values."
IndexNo = See section 7, "Parameter Values."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter Values."
Example: Command: get MTX:mem_512/60000/0/0/0/0/0 0 0
Response: OK get MTX:mem_512/60000/0/0/0/0/0 0 0 -7760
Meaning: Query the 1ch level of the DCA fader with raw values.
The 1ch level of the DCA fader is -77.60.
2-11) Normalized value parameter query
Command Option 1 Option 2 Option 3 Description
getn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/
Ypos/PrmNo/IndexNo
0 0 Normalized value parameter
query request
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Xpos = See section 7, "Parameter Values."
Ypos = See section 7, "Parameter Values."
IndexNo = See section 7, "Parameter Values."
Response
Response string Description
OK gen MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value)
Normalized value parameter query response
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Xpos = See section 7, "Parameter Values."
Ypos = See section 7, "Parameter Values."
IndexNo = See section 7, "Parameter Values."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter Values."
Example: Command: getn MTX:mem_512/60000/0/0/0/0/0 0 0
Response: OK getn MTX:mem_512/60000/0/0/0/0/0 0 0 408
Meaning: Query the 1ch level of the DCA fader with normalized values.