3. Command Specications
3.2.2. Parameter change notication
1-5) Parameter change notication raw value
Parameter change notication normalized value
Command Option 1 Option 2 Option 3 Option 4 Option 5 Description
NOTIFY set MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo
0 0 "(value)" "(string)" Parameter change
raw value
NOTIFY setn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo
0 0 "(value)" "(string)" Parameter change
normalized value
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Xpos = See section 7, "Parameter Values."
Ypos = See section 7, "Parameter Values."
IndexNo = See section 7, "Parameter Values."
"(value)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter Values."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter Values."
Example: Notication: NOTIFY set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 "-77.60"
Meaning: DCA Fader 1ch level was changed to "-77.60."
1-6) Scheduler on/off change notication
Command Option 1 Option 2 Option 3 Option 4 Option 5 Description
NOTIFY set(setn) MTX:EvntScd_On 0 0 1 "1" Scheduler on
0 "0" Scheduler off
* For setn, option 4 is expressed using a normalized value.
Example: Notication: NOTIFY set MTX:EvntScd_On 0 0 1 "1"
Meaning: The scheduler was turned on.
1-7) Parameter change notication
Command Option 1 Option 2 Option 3 Description
NOTIFY mtr MTX:mtr_MemNo/UniqueId/meter level (meter) Level meter value
gr gr meter value
MTX:mtr_MemNo/UniqueId/hold hold Hold meter value
Details: MemNo = See section 8, "Meters."
UniqueId = See section 8, "Meters."
(meter) = See section 5, "Meter Values."
Example: Notication: NOTIFY mtr MTX:mtr_512/20020/meter level 71 71 71 71 71 71 69 68
* The meter value is expressed using a 2-digit hexadecimal.
Meaning: Output levels for ch1 to 8 Level are sent.
3.2.3. Current snapshot (preset) number change notication
1-8) Current snapshot (preset) number change notication
Command Option 1 Description
NOTIFY sscurrent (index) Current preset number change notication
Details: (index) = Current preset index number
Example: Notication: NOTIFY sscurrent 10