User Manual

Table Of Contents
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.3.1 rev13
16
3. Command Specications
3.2.2. Parameter change notication
1-5) Parameter change notication raw value
Parameter change notication normalized value
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Option 2 Option 3 Option 4 Option 5 Description
NOTIFY set MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo
0 0 "(value)" "(string)" Parameter change
raw value
NOTIFY setn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo
0 0 "(value)" "(string)" Parameter change
normalized value
Details: MemNo = See section 7, "Parameter List."
UniqueId = See section 7, "Parameter List."
ElmNo = See section 7, "Parameter List."
Xpos = See section 7, "Parameter List."
Ypos = See section 7, "Parameter List."
PrmNo = See section 7, "Parameter List."
IndexNo = See section 7, "Parameter List."
"(value)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Notication: NOTIFY set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 "-77.60"
Meaning: DCA Fader 1ch level was changed to "-77.60."
MRX7-D
Command Option 1 Option 2 Option 3 Option 4 Option 5 Description
NOTIFY set MTX:Index_IndexNo 0 0 "(value)" "(string)" Parameter change raw value
NOTIFY setn MTX:Index_IndexNo 0 0 "(value)" "(string)" Parameter change normalized value
Details: IndexNo = Index number assigned in Remote Control Setup List
"(value)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Notication: NOTIFY set MTX:Index_1 0 0 -7760 "-77.60"
(V2.02 or earlier NOTIFY set MTX:Index_001 0 0 -7760 "-77.60")
Meaning: Level of the parameter assigned to Index 1 in Remote Control List was changed to "-77.60".
Important: If a parameter is assigned to multiple Index numbers in the Remote Control Setup List, Notication is only
provided to the lowest assigned Index number.
1-6) Scheduler on/off change notication
Command Option 1 Option 2 Option 3 Option 4 Option 5 Description
NOTIFY set(setn) MTX:EvntScd_On 0 0 1 "1" Scheduler on
0 "0" Scheduler off
* For setn, option 4 is expressed using a normalized value.
Example: Notication: NOTIFY set MTX:EvntScd_On 0 0 1 "1"