MRX7-D
Command Option 1 Option 2 Option 3 Option 4 Description
setr MTX:Index_IndexNo 0 0 "(value)" Relative value set
command.
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = relative value to increase or decrease.
(See "Fader Parameter" table in section 6 Parameter Value Details )
Note: This command is available only for fader type parameters. See "Remarks" column in section 7 Parameter List for
information regarding which parameters support this command.
The Parameter will be set to a new value which equals the sum of the parameter's original value and the relative value
given by this command.
The parameter value range is 0 - 1023 as shown in the "Fader Parameter" table in section 6 Parameter Value Details.
For example, when the relative value is set to 64, 16 level steps can be achieved from the remote controller.
(1024/64 = 16)
Response
Response string Description
OK setr MTX:Index_IndexNo 0 0 (value) Normalized value parameter setting response
OKm setr MTX:Index_IndexNo 0 0 (value)
* If the requested parameter value is outside the range, the value is adjusted within the range and set.
If this occurs, the result notication will be OKm instead of OK.
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = relative value to increase or decrease.
(See "Fader Parameter" table in section 6 Parameter Value Details )
Example: Command: setr MTX:Index_1 0 0 100
Response: OK setr MTX:Index_1 0 0 -1900
(V2.02 or earlier OK setr MTX:Index_001 0 0 -1900)
Meaning: Set the parameter assigned to index 1 in Remote Control Setup List to 100 step increase.
Level of the parameter which is assigned to index 1 in Remote Control Setup List was set to "-19.00".
2-16) Scheduler setting
Command Option 1 Option 2 Option 3 Option 4 Description
set(setn,sett) MTX:EvntScd_On 0 0 1 Scheduler on
0 Scheduler off
* For setn, specify a normalized value; for sett, specify option 4 with a character string.
Response
Response string Description
OK set MTX:EvntScd_On 0 0 1 "1" Scheduler enabled response
OK set MTX:EvntScd_On 0 0 0 "0" Scheduler disabled response
Example: Command: set MTX:EvntScd_On 0 0 1
Response: OK set MTX:EvntScd_On 0 0 1 "1"
Meaning: Enable the scheduler.
The scheduler was enabled.