User Manual

Nu
mbe
r
Message Severity Content Action Single/Co
ntinuing
66 Error Occurred At
Secondary Port
Warning In Redundant mode, the
Dante Primary circuit is
operating correctly, but the
Secondary circuit is not
connected.
* Only if connection had
once been confirmed, and
then been disconnected
If connection of the
Secondary circuit is
needed, check whether it
may have malfunctioned.
Continuin
g
67 Wrong Word Clock Warning A problem was detected in
the word clock.
- In Dante Controller,
correctly set the word
clock of the entire system.
- Make sure that the Fs
(sampling frequency)
setting is the same for the
devices whose audio is
patched.
Continuin
g
69 Dante Port Is Not
Connected
Warning In Redundant mode, the
Dante Primary circuit is
operating correctly, but the
Secondary circuit is not
connected.
* This is displayed only if
connection had once been
confirmed, and then been
disconnected.
Make sure that the Dante
circuit is correctly
connected.
Continuin
g
16. Power Amplifiers : PC-series