User Manual

Table Of Contents
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V4.0.0 rev14
102
7. Parameter List
7.2. MRX7-D
Parameter Name MIN MAX unit Remarks
ANALOG IN Ch Gain -6 66 dB
+48V OFF ON - 0:OFF
1:ON
ANALOG OUT Ch Polarity NORMAL INVERTED - 0:NORMAL
1:INVERTED
Gain -96.0 24.0 dB dB x 10
e.g. -14.5dB x 10 = -145
SLOT OUT Ch Polarity NORMAL INVERTED - 0:NORMAL
1:INVERTED
Gain -96.0 24.0 dB dB x 10
e.g. -14.5dB x 10 = -145
DANTE OUT Ch Polarity NORMAL INVERTED - 0:NORMAL
1:INVERTED
Gain -96.0 24.0 dB dB x 10
e.g. -14.5dB x 10 = -145
Acoustic Echo Canceller AEC ON OFF ON - 0:OFF
1:ON
NR ON OFF ON - 0:OFF
1:ON
Threshold -72 -25 dB
Ambient Noise Compensator Ambient Threshold -∞ 0.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
Gap Threshold -∞ 0.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
Time 0.1 5.0 s sec x 10
e.g. 3.8sec x 10 = 38
Program MaxGain 0.0 18.0 dB dB x 10
e.g. 5.2dB x 10 = 52
MinGain -18.0 0.0 dB dB x 10
e.g. -14.5dB x 10 = -145
Ratio* 0.5:1 2.0:1 - * See "6.2.4.3. ANC" in "6. Parameter Values"
ResponseTime 1 60 s
On ON OFF ON - 0:OFF
1:ON
Audio Detector Detect Threshold -90 0 dB
DetectionIndicator
OFF ON - 0:OFF
1:ON
Hold 0.1 10.0 s sec x 10
e.g. 3.8sec x 10 = 38
Innite Hold OFF ON - 0:OFF
1:ON
On ON OFF ON - 0:OFF
1:ON
Auto Gain Control Compensator
ResponseTime*
100m 5.0 s * See "6.2.2.4. AGC" in "6. Parameter Values"
Level 1 5 -
NoiseGateOn OFF ON - 0:OFF
1:ON
On ON OFF ON - 0:OFF
1:ON
Combiner Room Combiner BGM Source* BGM1 BGM4 - * See "6.3.3.1. Room Combiner" in "6.
Parameter Values"
ON OFF ON - 0:OFF
1:ON
Level -∞ 10.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
"setr" command is available for this parameter
Paging ON OFF ON - 0:OFF
1:ON
Level -∞ 10.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
"setr" command is available for this parameter
RoomIn ON OFF ON - 0:OFF
1:ON
Level -∞ 10.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
"setr" command is available for this parameter
RoomOut ON OFF ON - 0:OFF
1:ON
Level -∞ 10.00 dB dB x 100
e.g. -73.60dB x 100 = -7360
"setr" command is available for this parameter
Combine ON OFF ON - 0:OFF
1:ON