2 OSCILLATOR LEVEL field
Indicates the frequency and level of the currently-selected oscillator. A meter in this field
indicates the output level of the oscillator. Press the LEVEL knob to adjust the oscillator
level using the multifunction knob.
3 OSCILLATOR MODE field
Indicates the currently-selected oscillator mode. Pressing the MODE button repeatedly
will switch modes.
4 OSCILLATOR ASSIGN field
An indicator lights to indicate the currently-selected oscillator output destination (input
channels or buses). Use the tabs on the left to select channels or buses to display.
NOTE
In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
5 OSCILLATOR OUTPUT button
Turns the oscillator output on or off.
OSCILLATOR window
You can make detailed settings for the oscillator. This window appears when you press the
OSCILLATOR display button in the MONITOR screen.
1 OSCILLATOR MODE buttons
Select one of the following four operating modes when the oscillator is turned on:
2 Parameter field
Enables you to set the oscillator parameters. The controllers and their functions in this
field vary depending on the selected mode.
Mode = SINE WAVE
LEVEL knob..........Indicates the output level of the sine wave. You can adjust the
value by using the multifunction knob.
FREQ knob ...........Indicates the frequency of the sine wave. You can adjust the value
by using the multifunction knob.
Mode = SINE WAVE 2CH
LEVEL knob (ODD/L) ........ Indicates the output level of the sine wave on the ODD/L
side. You can adjust the value by using the multifunction
knob.
FREQ knob (ODD/L).......... Indicates the frequency of the sine wave on the ODD/L
side. You can adjust the value by using the multifunction
knob.
LEVEL knob (EVEN/R) ...... Indicates the output level of the sine wave on the EVEN/
R side. You can adjust the value by using the
multifunction knob.
FREQ knob (EVEN/R)........ Indicates the frequency of the sine wave on the EVEN/R
side. You can adjust the value by using the multifunction
knob.
By default, ODD(L) is set to 1kHz and EVEN(R) is set to 400Hz. At this time, there are
two meters (L and R).
21
5
4
3
SINE WAVE A sine wave will be output continuously.
SINE WAVE 2CH
Two sine waves of different frequencies will be output
separately.
PINK NOISE Pink noise will be output continuously.
BURST NOISE Pink noise will be output intermittently.