User Manual

Table Of Contents
Channel Job
Reference Manual
74
RECALL SAFE MODE window
1 CLEAR ALL button/SET ALL button
The CLEAR ALL button turns off (disables) the Recall Safe function (that is currently set
for individual channels) and the Global Recall Safe function simultaneously. The SET ALL
button turns on (enables) these functions simultaneously.
NOTE
If you press the CLEAR ALL button, the Recall Safe function will temporarily be disabled.
However, the parameters that would be affected by the Recall Safe function will not change.
2 Safe channel display section
Indicates the channels that are currently set to Recall Safe.
3 SET BY SEL button
Enables you to use the [SEL] keys on the panel to select channels that will be affected by
the Recall Safe function. Turn this button on, and then press the [SEL] key for the
channel to which you want to apply Recall Safe. Recall Safe will turn on. Press the same
[SEL] key once again to de-select the channel.
4 GLOBAL RECALL SAFE display section
Indicates the parameters and racks that will be affected by the Recall Safe function for
all scenes. Press this section to open the GLOBAL RECALL SAFE window.
These buttons correspond to the following parameters.
NOTE
If a dual-type GEQ rack or Premium rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the setting for racks A and B will be linked.
5 Channel select button
Selects the channel for which you want to set the Recall Safe function.
NOTE
Switching channels using this button will not affect the channel selection on the top panel.
6 Selected channel display
This area indicates the icon, number, color, and name of the currently-selected channel.
7 APPLY TO ALL INPUT button (input channels only)
Turn on this button to apply the Recall Safe parameter selection for one input channel
to all other input channels.
Turn this on if you want to apply Recall Safe to the same parameters for all input
channels.
8 APPLY TO ALL OUTPUT button (shown only for output channels)
Turn on this button to apply Recall Safe parameter selection for one output channel to
all other output channels.
Turn this on if you want to apply Recall Safe to the same parameters for all output
channels.
9 Safe parameter select button (excluding DCA groups)
Selects Recall Safe parameters for the selected channel.
The button indication varies depending on the channel type.
1
3
5
9
2 4
6
7 0A 8
All parameters are affected by Recall Safe on these channels.
Some parameters are affected by Recall Safe on these channels.
Recall Safe has been canceled on these channels.
INPUT PATCH All input patches
INPUT NAME All input channel names
OUTPUT PATCH All output patches
OUTPUT NAME All output channel names
HA All I/O devices, and HA-related parameters for external head amps
CH LINK All channel link group settings
MUTE GROUP
NAME
Setting a MUTE group name
Custom fader bank Custom fader bank settings
GEQ RACK
EFFECT RACK
PREMIUM RACK
Apply Recall Safe to GEQ racks 1 - 16, Effect racks 1 - 8, Premium racks 1
- 8 individually.
FADER BANK
SELECT
FADER BANK selection status, MASTER FADER assign status