26.4. Setting method for MTX5-D/MTX3
When the DCP component in MTX5-D/MTX3 is clicked, the DCP dialog opens and settings can be made.
26.4.1. DCP component settings
Double-click the DCP component to open the component editor.
[Library]
You can store 32 sets of Wireless DCP settings in the Library.
The Library stores the settings of all DCPs connected to the MTX. Also, the DCP Library can be recalled at
the same time as the MTX preset recall. Make settings in the dialog box that appears when you press the
[Recall Settings] button in the “Presets” area.
Recalling the Library will collectively recall all DCPs (up to 8 units) connected to the
MTX. If you want to select the DCP to recall, click the [Recall Filter] button in the
“Presets” area and make filter settings in the dialog box that appears.
[Save] button
This button stores an item in the library.
The [Parameter Assign] tab and [Dimmer & Lock] tab settings will be saved.
[Load] button
Load Library.
Expand the settings to the "Parameter Assign" tab and the "Dimmer & Lock" tab.
[Library] list
Select the library item that you want to save or load. The currently-loaded library item is shown in
bold characters.
By double-clicking a previously-saved library item, you can edit its name.
[Copy] button