User Manual

Owner’s Manual
23
Warning Messages
Warning Messages
The indicators will light and/or flash as shown until the
cause is resolved.
If the green [SYNC] indicator is unlit, the unit’s clock is
unconfirmed.
If the green indicator is flashing, the unit is the clock
master.
If the green indicator is lit, the unit is the clock slave and the
clock is synchronized.
Information Messages
The indicators will remain lit and/or flashing cyclically to
report the status.
If the orange [SYNC] indicator is unlit, the unit is operating
normally.
If the green [SYNC] indicator is unlit, the unit’s clock is
unconfirmed.
[SYNC] Indicators Description Possible Solution
The word clock is
not set correctly.
Set the clock mas-
ter and sampling
frequency cor-
rectly on the
RSio64-D-native
device or in Dante
Controller.
Dante Network cir-
cuit is broken.
Make sure that the
Ethernet cables
are not removed or
short-circuited.
Other Dante-com-
patible devices
cannot be found
due to an incor-
rectly-wired Dante
Network.
Make sure that the
Ethernet cables
are connected cor-
rectly.
[SYNC] Indicators Description Possible Solution
A non-GbE-com-
patible device is
connected.
When transferring
audio via Dante,
use device that
supports GbE.
The [SECOND-
ARY] connector
has taken over
communications
during redundant
networ
k operation.
Check the circuit
connected to the
[PRIMARY] con-
nector.
An abnormality
has occurred on
the circuit con-
nected to the
[SECONDARY]
connector during
redundant net-
work operation.
Check the circuit
connected to the
[SECONDARY]
connector.
(orange)
Flash
Flash x2
(orange)
Flash x3
(orange)
Light
(green)
Light
or flash
(orange)
FlashLight
or flash
(green) (orange)
Flash x2Light
or flash
(green) (orange)
[SYNC] Indicators Description Explanation
Muted during
startup, or in the
process of syn-
chronization.
Please wait until
started has com-
pleted or until the
unit has finished
synchronization. It
may take up to 45
seconds for com-
pletion.
The unit is func-
tioning correctly as
the word clock
master.
The unit is operat-
ing as the word
clock master.
The unit is func-
tioning correctly as
the word clock
slave.
The unit is operat-
ing as the clock
slave and the clock
is synchronized.
Lit
(orange)
(green)
Flash
(green)
Lit