User Manual

29
CL/QL
COMP COMP
DE-
ESSER
Other types Off
<Key to table> Blue field and arrow means compatible setting
Orange field and arrow means setting replaced by substitution
6) PAN/BALANCE parameters are converted when configurations match (see table below). When
RIVAGE PM configurations and CL/QL configurations do not match, the converter will substitute a
value which maintains the rule that odd channel signals are assigned to L and even signals to R.
Input to Stereo & Input to Mix/Matrix: Pan/Balance -Input Channel 1-72
RIVAGE
PM
Pan mode
Balance mode (Pair)
Pan for Left Ch
Pan for Right Ch
Balance for Left & Right Ch
CL/QL
Pan: Copy
Pan: Copy
Pan: L63
Pan: R63
Pan mode (only available mode)
RIVAGE
PM
Pan mode (no Pair)
Pan: Copy
Pan: Copy
CL/QL
Pan for Left Ch
Pan for Right Ch
Pan mode
7) Converts with RIVAGE PM Insert 1. When there is no same insert point or same direct out point in
the convert destination, the converter will substitute an appropriate value.
Insert Point -Input Channel
RIVAGE
PM
Pre Filter
Pre EQ
Pre DYN1 Pre DYN2
Pre Fader
Post On
CL/QL
Pre EQ
Pre Fader
Post On
Insert Point -Output Channel
RIVAGE
PM
Pre Filter
Pre EQ
Pre DYN
Pre Delay
Post Fader
Post On
CL/QL
Pre EQ
Pre Fader
Post On
Direct Out Point -Input Channel
RIVAGE
PM
Pre Filter
Pre EQ
Pre DYN1 Pre DYN2
Pre Fader
Post Fader
Post On
CL/QL
Pre HPF
Pre EQ
Pre Fader
Post On
8) CL/QL four-band EQ and RIVAGE PM EQ band 1, 2, 7, 8 are converted. RIVAGE PM EQ A or B
settings, which are currently selected, are converted to CL/QL EQ settings. CL/QL EQ settings are
converted to RIVAGE PM EQ A settings. Although on the RIVAGE PM the HPF and LPF settings
are separate from the EQ settings, RIVAGE PM HPF or LPF settings are prioritized from RIVAGE
PM EQ settings and converted to CL EQ settings when the RIVAGE PM HPF or LPF is ON.
CL/QL LEGACY TYPE I/TYPE II are not converted to RIVAGE PM LEGACY because they are
different effects.
9) KEY IN SOURCE is converted as shown in the table below.
RIVAGE
PM
Self Pre EQ
Self Post EQ
Other types
Default
CL/QL
Self Pre EQ
Self Post EQ
Default
Other types
10) RIVAGE PM DYNAMICS A or B settings, which are currently selected, are converted to CL/QL
DYNAMICS settings. CL/QL DYNAMICS settings are converted to RIVAGE PM DYNAMICS A
settings. Output DYNAMICS parameters are converted when configurations match (Refer to below
table). RIVAGE PM LEGACY COMP and COMP260 are converted to CL/QL COMP. CL/QL
COMP are converted to RIVAGE PM LEGACY COMP. DYNAMIC parameters will be set to default
values when the configurations do not match. RELEASE parameters are converted to valid values
when the RIVAGE PM or the CL/QL is using the 48 kHz Wordclock.
Dynamics1
RIVAGE
Legacy
Comp
Comp260
Expander
Off
Other types
CL/QL
Comp
Comp
Expander
Other types
Off
11) Reproducibility of Recall Safe & Focus Recall
Refer to section 3.8, “Recall Filter” Treatment.