User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/output characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
Reference Manual
143
Parametric EQ operations
In addition to the standard 4-band EQ, CL series consoles also feature an 8-band parametric
EQ (PEQ) that can be rack mounted. You can mount this PEQ in GEQ racks 1-16 and patch
it to the insert-out/in of an input channel (GEQ 1-8 rack only), a MIX/MATRIX channel, or a
STEREO/MONO channel. You can also mount it in EFFECT racks 1-8 (FX 1-8) and patch it
to the insert-out/in of an input channel, MIX/MATRIX channel or STEREO/MONO channel.
The gain of each band can be adjusted using the Centralogic section’s faders and [ON] keys.
The following type of PEQ is provided.
8BandPEQ
This is a monaural 8-band PEQ. There are also an independent HPF, LPF, and 3 notch filters.
Two 8BandPEQ units (shown as “A” and “B” respectively) can be mounted in a rack, and
therefore you can use two channels of input and output for each rack.
Inserting a PEQ in a channel
This section explains how to insert a PEQ into the selected channel for use.
NOTE
• You can view the input and output levels of the PEQ in the rack in the GEQ or EFFECT field.
• For details on PEQ operations, refer section “PEQ EDIT window” (page 143).
PEQ EDIT window
1 PEQ graph
Displays the parameter values for the PEQ and filter.
2 INPUT button
Press this button to open the CH SELECT window, in which you can select the input
source of the rack. The operating procedure is the same as for the INPUT button in the
GEQ field.
3 OUTPUT button
Press this button to open the CH SELECT window, in which you can select the output
destination of the rack. The operating procedure is the same as for the OUTPUT button
in the GEQ field.
4 LIBRARY button
Press this button to open the PEQ Library window.
5 DEFAULT button
Press this button to restore the default parameter setting.
STEP
1. Refer to steps 1-8 in “Virtual rack operations” (page 136) to mount a PEQ in a rack
and set its input source and output destination.
2. In the GEQ field rack or the EFFECT field rack, press the rack container in which you
mounted the PEQ.
3. If you’re using a stereo source, press the RACK LINK button to link the two PEQ units.
4. Press the PEQ ON/OFF button to turn the PEQ on.
5
E
F
4 31 2 76 8
D
B
0
9
A
C