DCA Roll-out function
You can now access all of the channels assigned to a DCA group simultaneously through the
fader banks.
This function enables flexible fader operations. For example, while controlling the DCA fader
in the Centralogic section, you can use the Roll-out function to access (roll-out) and control
the faders (assigned to the corresponding DCA group) through the fader bank located to the
left of the Centralogic section. Alternatively, you can control the faders rolled out to the
Centralogic section via DCA Roll-out, while operating the DCA faders through the fader bank
on the left.
DCA ROLL-OUT operation
NOTE
You cannot turn Roll-out mode on while operating the DCA group (for example, while assigning
channels or editing the group name).
Even if Roll-out mode is turned on while you are controlling a GEQ via faders, you cannot edit
the DCA group using the faders.
If the number of channels assigned to the DCA group exceeds the number of faders in the block,
you can use the multifunction knob or the GAIN/PAN/ASSIGN knob to scroll the content of the
block from left to right. While the knob is turned, the message “DCA ROLL-OUT: DCA members
scrolling.” is displayed at the bottom of the screen.
If, for example, the DCA group to be operated is in the Centralogic section and the HPF/EQ
window is displayed, the HPF/EQ parameters for the multifunction knob cannot be operated. To
operate a parameter that is not assigned, use the [TOUCH AND TURN] knob.
All bank select keys in the block (to which the displayed channels belong) will light up.
If the faders are rolled out to the Centralogic section (block B), the IN/OUT select keys in the
Centralogic section will be disabled.
Bank select keys in blocks in which no faders are rolled out will operate normally.
When in DCA ROLL-OUT mode, you can exit this mode by pressing a Bank Select key. In that
case, the screen will switch to the bank for the key that was pressed.
Setting the DCA Roll-out function
NOTE
You cannot turn DCA Roll-out mode on if one of the following popup windows is open. If DCA
Roll-out mode is already turned on, opening one of the windows will cause DCA Roll-out mode
to quit.
- DCA/MUTE GROUP ASSIGN MODE popup window
- RECALL SAFE MODE popup window
STEP
1.
Use a bank select key to select the DCA group that you want to control, then press the
[SEL] key for that DCA group.
DCA Roll-out mode is engaged, and the faders that have been assigned to the DCA group will be
rolled out.
2. If you press the [SEL] key for another DCA group, faders that have been assigned to that
DCA group will be rolled out.
3. Press the same [SEL] key again to exit DCA Roll-out mode.
STEP
1. In the Function Access Area, press the CH JOB button.
2. Press the DCA GROUP button to access the DCA/MUTE GROUP ASSIGN MODE popup
window.
3. Press the DCA ROLL-OUT button.
4. Select a DCA group.
If you press a [SEL] key for a DCA group other than the selected one, the group selection will change.
5. Select a block (in which the DCA group is rolled out to the faders) and the alignment.
6. Press the CLOSE button to close the popup window.