User Manual

I/O rack settings for scene recall
(Reference Manual, p. 198)
For each CL series unit, you can specify which I/O rack the information saved on the CL series will be applied
to when the CL series is started up and when a scene is recalled. When there are multiple CL series units,
specify the settings so that a scene is recalled to an I/O rack from only one CL series.
Follow the steps below.
1. In the Function Access Area, press the SETUP button.
2. Press the DANTE SETUP button to access the DANTE SETUP popup window.
3. In the DE
VICE TYPE list, set the DEVICE TYPE for the I/O rack that you want recalled from the
currently selected CL series to an I/O rack indicated by “(w/RECALL)”.
4. In the same way, for other CL series units, specify the DEVICE TYPE setting to set whether or not a
scene is recalled to an I/O rack.
NOTE
General network settings (BIT/LATENCY/W. CLOCK) from the CL series where CONSOLE ID is set to #1
are applied globally.
The head amp of the I/O rack can even be operated from a CL series where “(w/RECALL)” is not set.
An I/O rack where “(w/RECALL)” is set for one CL series cannot be set with “(w/RECALL)” for a different
CL series.
C.S.G., Pro Audio Division
©2012 Yamaha Corporation
205YJ-A0