User Manual

R Remote Version 3 Users Guide 21
For RSio64-D
You can change the RSio64-D settings.
CARD NAME
This indicates the names of the cards installed in slots 1 to 4. If nothing is installed, ----” will
appear.
IN/OUT PORT
This indicates the number of input and output ports for the cards installed in slots 1 to 4. If no
card is installed, “--” will appear.
SLOT14 [LOCK] indicators
This indicates the word clock status for slots 1 to 4. If the word clock is operating normally, this
indicator will be green.
Off
There is no card in the slot. Or, an unsupported card is in the slot.
Green
(On)
LOCK
Indicates that a clock synchronized with the clock source selected with the [WORD
CLOCK] select key is being input from the card. If an external device is connected to
the corresponding slot, input/output is occurring properly between that device and the
RSio64-D. If the sampling frequency is close, this status may be displayed even if not
synchronized.
Green
(Flashing)
SYNC
ERROR
A valid clock is being input from the card, but is not synchronized with the clock
source selected with the [WORD CLOCK] select key. If an external device is connected
to the corresponding slot, input/output cannot occur correctly between that device and
the RSio64-D. Turn SRC ON for correct input/output.