User Manual

Table Of Contents
I/O devices and external head amps
V5.8 Reference Manual
183
Remotely controlling an amp
This section explains how to remotely control an amp unit that’s connected to the Dante connector.
I/O DEVICE screen (AMP page)
1 Display switch buttons
Press one of these buttons to view the corresponding I/O device.
For more information about VIRTUAL/CONFLICT/DUPLICATE displayed below this
button, refer to
1 on P.173, I/O device list”.
2 ID/Model name display
This shows the ID number, model name, and version of the I/O device.
3 DANTE SETUP button
Press this button to open the DANTE SETUP window, in which you can make settings
for the audio network.
For NEXO NXAMPmk2
1
Channel name
Displays the channel name (the speaker preset name for the NXAMP).
2 Output level meter
Displays the level of Voltage (amplifier output) and the level of Protect (gain reduction).
3 LIMIT status indicator
Lights when the limiter for amplifier protection is applied.
4 PROTECT status indicator
Lights when the limiter for speaker protection is applied.
5 VOLUME setting value
Displays the volume.
6 MUTE indicator
Indicates the currently set mute status.
7 Control status indicator
Indicates the control status of the device.
8 Device status indicator
Indicates the status of the device.
STEP
1. Press the AMP tab in the upper part of the I/O DEVICE screen.
2. Press the I/O device displayed on the I/O DEVICE screen (AMP page).
3. Set the output port on the OUTPUT PATCH window, as necessary.
Refer to step 7 in I/O device patching” (page 173).
1 2
3
1
2
4
3
6
5
8
7