User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Setup
V5.8 Reference Manual
221
If you set Surround mode, the BUS SETUP screen appears as shown below.
DATE/TIME button
Press this button to open the DATE/TIME window, in which you can set the date and time.
NETWORK button
Press this button to open the NETWORK window, in which you can set the network address.
Indicator field
This field displays various information about the console.
F BATTERY indicator
Indicates the status of the internal battery.
NOTE
The LOW or NO indication will appear if the battery runs down. In this case, immediately contact
your Yamaha dealer or a Yamaha service center listed at the end of the operating manual
(separate document) to have the backup battery replaced.
G POWER SUPPLY indicator
Indicates the currently-running power supply.
• INT .........................Internal
• EXT ........................PW800
H Version indicator
Indicates the version number of the main CPU, sub CPU, and Dante module.
CONSOLE LOCK button
This button executes the Console Lock function. If the console password has been set,
pressing this button will open the AUTHORIZATION window. Enter the correct password to
execute Console Lock.
If the console password has not been set, pressing this button will execute Console Lock
immediately.
CONTRAST/BRIGHTNESS field
This field enables you to set the LCD brightness and contrast.
I BANK A/BANK B buttons
Select a bank to which you want to save the brightness and contrast settings. You can
save two different settings in bank A and B, and switch between them if desired.
J CONTRAST NAME knob
Adjusts the contrast of the channel name display.
K BRIGHTNESS NAME knob
Adjusts the brightness of the channel name display.
BRIGHTNESS CH COLOR knob
Adjusts the brightness balance of the channel color and the channel name display.
BRIGHTNESS SCREEN knob
Adjusts the brightness of the display.
BRIGHTNESS PANEL knob
Adjusts the brightness of the panel LEDs.
BRIGHTNESS LAMP knob
Adjusts the brightness of the lamp connected to the LAMP connector.
User settings
User Level settings allow you to restrict the parameters that can be operated by each user, or
to change the settings of USER DEFINED keys and preference settings for each user.
Settings for each user can be stored as a “user authentication key” inside the console or
together on a USB flash drive, allowing users to be switched easily. This can be convenient in
the following situations.
• Unintended or mistaken operation can be prevented.
• The range of functionality operable by an outside engineer (guest engineer) can be
limited.
• In situations in which multiple operators alternate with each other, output settings etc.
can be locked to prevent unintended operations.
• Preferences of each operator can easily be switched.