User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Setup
V5.8 Reference Manual
273
REMOTE HA settings
Here’s how to select which of the multiple HA devices on the Dante audio network will be
mounted so that they can be used. Up to 8 units can be mounted for one CL series console.
A device with many channels occupies two racks. For such device, you can only mount on
odd numbered racks. Also, it is necessary to have two racks in a row. Up to four units can be
mounted.
DANTE SETUP window (REMOTE HA page)
1 CLEAR ALL button
Clears all HA devices in the list to an unmounted state.
2 REFRESH button
Updates the displayed list of HA devices on the Dante audio network.
3 HA device select buttons
Press one of these buttons to open the REMOTE HA SELECT window. The upper line of
the button shows the device label. The lower line of the button shows the model name
and the number of inputs and outputs. If no device has been mounted, the upper row
will indicate “---” and the lower row will show nothing.
For more information on VIRTUAL/CONFLICT/DUPLICATE shown below these buttons,
refer to
1 on P.173, “I/O device list.”
REMOTE HA SELECT window
1 DEVICE LIST
Shows a list of the HA devices on the Dante audio network.
2 WITH RECALL button
If this button is on, the settings saved in the CL series console will be applied to the HA
device when the CL series console starts up and when a scene is recalled.
3 DEVICE LIST select knob
Use the corresponding multifunction knob to select the HA device that you want to
mount.
NOTE
• Do not specify “WITH RECALL” if an HA device is shared by multiple CL series consoles and
settings have already been made on a different CL series console.
• The HA device can also be operated from a CL series console that is not set to “WITH RECALL.”
STEP
1. Press the REMOTE HA ASSIGN tab in the lower part of the DANTE SETUP window.
2. Press a HA device select button to access the REMOTE HA SELECT window.
3. Select the HA device to mount and press the OK button.
If you have changed the setting by pressing the WITH RECALL button, a
confirmation dialog box will appear. Press the OK button.
13 2
1
3
2