User Manual

Table Of Contents
Message Description
Low Battery! The backup battery's voltage is low.
Illegal IP Address! The IP address setting or gateway setting is incorrect.
USB Sample Rate Mismatch on USB. Console is
set to 48000Hz.
The Sample Rates of the DM3 and the computer connected to the USB TO
HOST connector are different. (Console : 48 kHz PC : 96.0 kHz)
Set the Sample Rate of the PC to 48 kHz.
USB Sample Rate Mismatch on USB. Console is
set to 96000Hz.
The Sample Rates of the DM3 and the PCconnected to the USB TO HOST
connector are different. (Console : 96 kHz PC : 48.0 kHz)
Set the Sample Rate of the PC to 96 kHz.
This device is not found No Dante compatible device found.
Dante Module Error! Dante module error, such as with DM3 or Tio1608-D.
Illegal MAC Address! Unable to communicate due to illegal DM3 MAC Address.
Device Fan has Malfunctioned! Fan error for device connected to the Dante network.
Memory Error! Memory error with Dante module, such as Tio1608-D.
Unit ID Duplicated! Identical Unit ID for devices connected to the Dante network.
Illegal DIP Switch Setting Illegal DIP Switch setting for device connected to the Dante network.
Version Mismatch Mismatch in version of Dante for device connected to the Dante network.
Dante audio resource overflow. Please reduce
Dante flows.
An excessive amount of audio data was sent over the Dante network.
Dante setting mismatch
The setting on the panel, such as of Tio1608-D, is different from its actual
operation.
This message is displayed when the Dante Device Lock is enabled for a
module such as Tio1608-D and there is a mismatch between the UNIT ID
switch on the panel and the actual UNIT ID, or when the UNIT ID is
operated after turning the power ON.
Under Synchronization
Settings are being made for a module, such as a Tio1608-D connected to
the Dante network.
Wrong Word Clock! Failed to sync with DM3 due to faulty Sample Rate setting.
Wrong Word Clock! (Dante Device)
The Sample Rate setting of a device connected to the Dante network is
faulty, so it cannot sync with the DM3.
Dante port does not have connection The Dante port is not connected.
Dante Connection Error! No device is connected to the Dante network.
Dante is working at 100Megabit, not 1Gigabit! Not linked up at 1 Gbps. Network switch does not support 1000BASE-T.
Dante has changed to Secondary Port!
The system has switched the port connected to the Dante network from
the PRIMARY port to the SECONDARY.
Error occurred at Secondary Port SECONDARY port was OFF when switched to the redundant network.
Operating as the word clock leader The DM3 is acting as the world leader clock.
Dante Module Restarted! The Dante module of the DM3 has restarted.
Dante Module Error! Please Restart the Console.
An error occurred with the Dante module of the DM3 that requires you to
restart the console.
If this message is displayed, restart the console.
Dante Connection Error! Please Restart the
Console.
Error in communication with the Dante module of the DM3.
If this message is displayed, restart the console.
This console is enrolled in a Dante Domain.
Operations are ignored as the DM3 is registered in the domain by the
Dante Domain Manager.
354