Control value H Control value L Parameter value
0 0 0
0 16 1
0 32 2
0 48 3
0 64 4
0 80 5
0 96 6
0 112 7
1 0 8
1 16 9
:
64 0 512
:
127 96 1022
127 127 1023
Program change (Cn)
<<Receive>>
When Single is selected and Program change Rx is ON, it is received when Rx Ch matches. However, when
Omni is ON, it is received regardless of the channel. When it is received, the scene memory is recalled
according to the settings of the Program Change Event.
<<Send>>
When Program change Tx is ON and scene memory is recalled, it is sent according to the settings of the
Program Change Event. If Single is selected, it is sent on the Tx Ch channel. If Multi is selected, when the
recalled scene memory is allocated to more than one Program Change No., the smallest Program Change No.
is sent for each MIDI Ch.
Either Single or Multi can be selected when setting Mode.
If Single
Rx Ch and Omni Ch or Tx Ch can be selected. When Bank is turned ON, you can specify the Bank in Bank
Select. Up to 16 Banks can be set.
If Multi
Rx Ch and Tx Ch become the same. An assignment table is configured for each MIDI Ch. Bank Select cannot
be used. Up to 16 MIDI Chs can be set.
STATUS 1100nnnn Cn Program change
DATA 0nnnnnnn nn Program number (0-127)
359