English Deutsch EN DE FR ES PT IT RU JA 日本語 Owner’s Manual Bedienungsanleitung Mode d’emploi Manual de instrucciones Manual do Proprietário Manuale di istruzioni Ɋɭɤɨɜɨɞɫɬɜɨ ɩɨɥɶɡɨɜɚɬɟɥɹ 取扱説明書 Ɋɭɫɫɤɢɣ Italiano Português Español Français AUDIO INTERFACE / INTERFACE AUDIO INTERFAZ DE AUDIO / INTERFACE DE ÁUDIO ȺɍȾɂɈɂɇɌȿɊɎȿɃɋ オーディオインターフェース
ATTE NTIO N RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. ATTENTION : POUR RÉDUIRE LES RISQUES D'ÉLECTROCUTION, NE PAS RETIRER LE CAPOT (OU LE DOS). NE CONTIENT PAS DE PIÈCES NÉCESSITANT L'INTERVENTION DE L'UTILISATEUR. POUR TOUTE INTERVENTION, FAIRE APPEL À DES PROFESSIONNELS QUALIFIÉS.
FCC INFORMATION (U.S.A.) 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. 2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Follow all installation instructions.
Tio1608-D2 Owner’s Manual -4-
Table of contents Included items......................................................... 5 Included items PRECAUTIONS ........................................ 6 • Owner's Manual (this document) • Power cord • Rubber feet ×4 Introduction .......................................... 8 Updating the firmware ............................................ Dante support ......................................................... Precautions when rackmounting ............................. Recessed Installation.....
PA_en_14 1/2 PRECAUTIONS Do not open • This product contains no user-serviceable parts. Do not attempt to disassemble the internal parts or modify them in any way. PLEASE READ CAREFULLY BEFORE PROCEEDING Please keep this manual in a safe place for future reference. Water warning • Do not expose the product to rain, use it near water or in damp or wet conditions, or place on it any containers (such as vases, bottles or glasses) containing liquids which might spill into any openings.
• Do not place the product in a location where it may come into contact with corrosive gases or salt air. Doing so may result in malfunction. Information • Before moving the product, remove all connected cables. About copyrights Maintenance • Copying of the software or reproduction of this manual in whole or in part by any means is expressly forbidden without the written consent of the manufacturer. • Remove the power plug from the AC outlet when cleaning the product.
Introduction Introduction Thank you for purchasing the Yamaha Tio1608-D2 I/O rack. The Tio1608-D2 is an I/O rack that features 16 channels of analog inputs and 8 channels of analog outputs. In order to take full advantage of this product's features, and to enjoy years of trouble-free use, please read this document before you begin using the product. After you have read this document, please keep it in a safe place.
Device features Front panel ղ ձ մ յ ն շ ոչ պ ջ ռճ 1 [INPUT] 1–16 Combination connectors that support both XLR 3-pin cable connectors and TRS phone plug. Use these connectors to connect mics and instruments. Nominal input level is -62 dBu to +10 dBu. When connecting a cable that uses an XLR 3-pin cable connector, make sure you supply +48 V phantom power to any devices that require it.
Device features 7 [QUICK CONFIG FOR TF] Turns Quick Config on and off. Set this switch setting to OFF if Quick Config is not used or multiple mixers are connected via a network. Turn the unit off before changing the [QUICK CONFIG FOR TF] position. If this setting is set while the power is ON, it is not applied in the main unit until the power is switched OFF and ON. See "Connection methods" (page 14) for information about Quick Config. 8 [SYSTEM] Indicate the status of the Tio1608-D2.
Device features ձ ղ ճ 1 [AC IN] մ ն շ English Rear panel յ 4 DIP switches Connect the included power cord. When connecting to a power outlet, first connect the power cord to the unit, then connect the power cord to the power outlet. CAUTION Make sure the unit is turned off before connecting or disconnecting the power cord. 2 Cooling vent The Tio1608-D2 contains a cooling fan. The cooling air is exhausted here, so please be careful not to block this vent.
Device features • Switches 5 and 6 (IP address mode) These switches determine how the unit's IP address is set. NOTE If switches 7 and 8 are set to the "update mode" or "diagnostic mode" positions, the unit will not be reset. • Switches 3, 7 and 8 (Tio1608-D compatibility mode) This mode is used to connect to older models that are not compatible with the Tio1608-D2. In the compatibility mode, the sampling frequency is set to the maximum 48 kHz and external devices recognize Tio1608-D2 as Tio1608-D.
Device features English 5 Dante [PRIMARY]/[SECONDARY] etherCON CAT5 connector that connects the unit to a Dante device, such as a NY64-D digital audio interface card. When DIP switch 4 is set to the daisy-chain connection position (i.e., up position), signals received on one connector are sent out via the other connector. When DIP switch 4 is set to the redundant connection position (i.e., down position), the [SECONDARY] functions as a backup and carries the same signals as the [PRIMARY].
Connection methods Connection methods This section explains the different methods for connecting the Tio1608-D2 to other Dante devices. To connect to a non-TF series mixer, refer to the mixer instruction manual. 4. Use Ethernet cables to connect the Tio1608-D2 to the NY64-D card (installed in the TF series mixing console) or to other Tio1608-D2 units in a daisychain configuration, as shown below.
7. To assign the Tio1608-D2 inputs to the TF series mixing console, set the input select on the console's INPUT screen to "SLOT". Manual setup If Quick Config is not used or if connecting to a mixer that does not support Quick Config, configure settings manually based on the given connection environment. Tio1608-D2 procedure 1. With the unit turned off, set the [QUICK CONFIG FOR TF] on the front panel to the [OFF] position. 2.
Troubleshooting Troubleshooting Troubleshooting Issue No power, power indicator does not light Unit is not receiving an input signal Cause Solution Power cord not connected. Make sure the power cord is connected (page 11). The power switch is turned off. Set the power switch to the "on" position. If you still cannot resolve the problem, please contact your nearest Yamaha representative. Cables not connected properly. Make sure all cables are connected properly.
How to read the indicators How to read the indicators English You can use the [SYSTEM] and [SYNC] to confirm the unit's status. The indicators can relay operational status, error status, and warnings. Error status If one of the following errors has occurred, the device will not operate. Until the error is resolved, the green [SYSTEM] will be turned off, and all indicators for all I/O channels will continue to flash. In addition, certain errors will cause the red [SYSTEM] to light or flash.
How to read the indicators Warnings The indicators will light and/or flash as shown until the cause is resolved. If the green [SYNC] is unlit, the unit’s clock is unconfirmed. [SYNC] Off Off Off Description Possible Solution Clock settings are incorrect. Check the clock leader and sampling frequency settings of the Tio1608-D2 and Dante Controller. Unit not connected to Dante network. Make sure the cables are not damaged and that they are connected properly.
Specifications Specifications English General Specifications Output impedance of signal generator: 150 ohms Measured with another Tio1608-D2 through Dante network. Frequency Response INPUT1-16 Fs = 20Hz-20kHz, refer to the nominal output level @1kHz Output 600Ω Total Harmonic Distortion Input INPUT1-16 RL OUTPUT 1-8 Conditions GAIN: +66dB. Min. Typ. Max. Unit -1.5 0.0 0.5 dB Min. Typ. Max. Unit Fs = 44.
Specifications AC Cable Length and Temperature Range Conditions Min. Typ. Max. Unit 0 40 °C -20 60 °C Connector balanced / Unbalanced AC Cable Length 2.5 Temperature Range Operating temperature range Storage temperature range m Dimensions (W x H x D) & Net weight 480(W) x 88(H) x 364(D) mm, 5.7kg Input Output Digital I/O Character Analog input characteristics Input Terminals INPUT1-16 Actual Load Impedance GAIN +66dB 7.
Specifications English Dimensions (10) Español Français 349 354 364 Deutsch Tio1608-D2 88 Português 480 日本語 Русский Italiano Unit: mm - 123 - Tio1608-D2 Owner’s Manual
MEMO Tio1608-D2 Owner’s Manual - 126 -
- 127 - Tio1608-D2 Owner’s Manual
Yamaha Pro Audio global website https://www.yamahaproaudio.com/ Yamaha Downloads https://download.yamaha.