User Manual

Device features
-
12
-
Owner’s Manual
Tio1608-D2
Switches 3, 7 and 8 (Tio1608-D compatibility
mode)
This mode is used to connect to older models that are
not compatible with the Tio1608-D2.
In the compatibility mode, the sampling frequency is
set to the maximum 48 kHz and external devices
recognize Tio1608-D2 as Tio1608-D.
- Activating the Tio1608-D compatibility mode
Configure the dip switches as shown above for
"Tio1608-D compatibility mode" and then switch the
power ON. When the red indicators on the front panel
stop flashing and only the green indicators are
flashing, that indicates the compatibility mode has
been successfully activated. Then switch the power
OFF, reconfigure the dip switch settings appropriately,
and switch the power back ON before using the
system. The green [SYSTEM] indicators will flash for
about 20 seconds only after switching to the Tio1608-
D compatibility mode.
- Canceling the Tio1608-D compatibility mode
Configure the dip switches as shown above for
"Cancels the Tio1608-D compatibility mode" and then
switch the power ON. When the red indicators on the
front panel stop flashing and only the green indicators
are flashing, that indicates the compatibility mode has
been successfully canceled. Then switch the power
OFF, reconfigure the dip switch settings appropriately,
and switch the power back ON before using the
system.
Switch 4 (Dante SECONDARY port mode)
This switch determines the operating mode of the
Dante [SECONDARY].
When Quick Config is used, these switches are
disabled.
Switches 5 and 6 (IP address mode)
These switches determine how the unit's IP address is
set.
Switches 7 and 8 (start up mode)
These switches determine how the unit starts up
during start up mode. When set to "refresh" mode, the
settings of the mixer are applied when the unit starts
up. When set to "resume" mode, the unit returns to
the same state as the last time it was used.
When Quick Config is used, the "normal operation"
mode settings are disabled.
NOTE
If switches 7 and 8 are set to the "update mode" or
"diagnostic mode" positions, the unit will not be reset.
Switch
position
Operating mode
Tio1608-D compatibility mode
Cancels the Tio1608-D compatibility mode
(initialize mode)
Switch
position
[SECONDARY] operating mode
Daisy chain connection
Redu ndant connection
NOTE
When the Switch 4 is set to "Redundant connection", the
head amp control function (page 15) is only available via
the Dante [PRIMARY].
378
378
4
4
Switch
position
IP address mode
Auto IP (link local)
DHCP
Static IP Auto (192.168.0.ID)
Static IP Manual
The IP address is specified from an
external device such as R Remote V3.
Switch
position
Start up mode
REFRESH mode (normal operation)
RESUME mode (normal operation)
Update mode
Diagnostic mode
NOTE
Update mode and diagnostic mode are used when
performing maintenance on the unit. Normally you will not
use these modes.
Update mode and diagnostic mode can be enabled even
when using Quick Config. Normally you will not use these
modes.
5 6
5
6
5 6
5 6
7
8
7 8
7
8
7 8