21
The word clock master has
become unlocked.
Make sure that the word clock signal is being
input correctly.
Error Continuing
22
The digital signal being input to
the [YDIF IN] connector is not
synchronized to the word clock
of this device.
Make sure that YDIF cables are properly
connected.
Use cables that meet the required
specifications.
Error Single
23
The digital signal being input to
the [YDIF IN] connector is not
continuously synchronized to
the word clock of this device.
Error Continuing
24
The digital signal being input to
the slot is not synchronized to
the word clock of this device.
Either input a signal that is synchronized, or
specify the slot as the word clock master.
Warning Single
25
The digital signal being input to
the slot is not continuously
synchronized to the word clock
of this device.
Warning Continuing
26
The digital signal being input to
the Dante connector is not
synchronized to the word clock
of this device.
Either input a signal that is synchronized, or
specify the Dante connectors as the word
clock master.
Warning Single
27
The digital signal being input to
the Dante connector is not
continuously synchronized to
the word clock of this device.
Warning Continuing
30
There is a problem with the
connection of the [YDIF IN]
connector.
Make sure that YDIF cables are properly
connected.
Use cables that meet the required
specifications.
Error Continuing
40
Duplicate IP addresses.
Change the IP addresses so that there are no
duplicates.
Error Continuing
41
IP address was not set within
60 seconds of startup.
Please check rear panel DIP switch 6 (IP
Setting). If DIP switch 6 is set to “PC,” use
MTX-MRX Editor or DHCP server to specify
the device IP address.
Warning Continuing
42
A device within the MTX/MRX
system was not found on the
network.
Power-on all devices in the system, and make
sure that they are correctly connected to the
network.
Error Continuing
43
Too many devices are
connected to the network.
Reduce the number of devices connected to
the network.
Error Single
44
A timeout has occurred in
synchronization to the time
server or the server reply is
invalid.
Check the time server condition or set another
time server.
Error Single
45
The host name of the time
server can not be resolved by
DNS server.
Check the setting of the time server, DNS
server address or make sure that the DNS
server works correctly.
Error Single
46
Dante received flow count
exceeded the limit.
Maximum Dante Flow rate exceeded. Try
changing parts of transmission flows to
Multicast using Dante Controller.
Error Single
Number Content Action Type