User Manual

Example 1) One remote location, and four microphones in the meeting room
MTX5-D/MY4-AEC System Setup Manual
10
Examples of adjusting the settings
Adjusting the volume of the audio signal from the remote location
Operate the fader of input channel 9. While you watch the level meter, adjust the input level so that the yellow indica-
tor lights occasionally.
Adjusting the volume of a microphone of the local location
In the “MY4-AEC” screen, click the [Near-end Mic.] button to access the parameter editing screen, and operate the
[GAIN] knob. While you watch the Mic In. meter, adjust the HA gain so that the yellow indicator lights occasionally.
Adjusting the volume of the speaker of the local location
Adjust the input level as described in “Adjusting the volume of the audio signal from the remote location” and
“Adjusting the volume of a microphone of the local location,” above.
If you don’t want the audio from the local microphone to be output from the speaker
In the “MATRIX” screen, turn off the sends of input channels 5 through 8.
If you want to connect recording/playback device
To record, connect your device to the MTX5-D’s “OUTPUT” 7 connector. To play back, connect your device to the
MTX5-D’s “ST IN” 2L connector. When recording, turn on the [ON] button of input channel STIN2L. When playing
back, turn on the [ON] button of output channel OUT7.
NOTE
Feedback may occur if you have connected a type of recording/playback device that outputs the input signal while recording is
paused. If feedback occurs, click the [ON] button of input channel STIN2L to turn it off. When playing back, turn this button back on.