User Manual

Table Of Contents
“Remote Control Setup List” dialog box
MRX Designer User Guide
125
“Remote Control Setup List” dialog box
The MRX can be controlled from an external device via the Dante [PRIMARY]/[SECONDARY]
connectors or the [RS-232C] connector. Here you can register MRX parameters, meters, snapshots,
and snapshot groups to be controlled from an external device.
Set up the external device as described in “MTX3 / MTX5-D / MRX7-D / XMV Series / EXi8 /
EXo8 Remote Controller Protocol Specification.
Parameters can be registered in the list in the following ways.
The following context menu appears when you right-click within the list.
Registration source Registration method
Design sheet
While holding down <Ctrl>, drag and drop a component onto the [PARAMETER]
field.
Right-click a component, and use [Add to Parameter Set] to select where it will
be registered.
Component editor / Link
Master editor / Parameter
setting window
While holding down <Ctrl>, drag and drop a parameter onto the [PARAMETER]
field.
Right-click a parameter, and use [Add to Remote Control List] to select where it
will be registered. Right-click somewhere other than on a parameter, and use
[Add to Remote Control List] to select where it will be registered; you can
register all parameters of the component or the meters of the component.
“Parameters” area
*1
*1. You can also use <Shift> or <Ctrl> to simultaneously register multiple components or parameters in the list.
Drag and drop the component or parameter onto the [PARAMETER] field.
Right-click a component or parameter, and use [Add to Remote Control List] to
select where it will be registered.
“Parameter Link Group”
area
While holding down <Ctrl>, drag and drop a parameter link group onto the
[PARAMETER] field.
Right-click a parameter link group, and use [Add to Remote Control List] to
select where it will be registered.
[Find]
If the [FUNCTION] field indication of the right-clicked item is Parameter, the component
editor that includes the corresponding parameter will open with that parameter selected.
If the [FUNCTION] field indication of the right-clicked item is Level Meter, the
corresponding component in the design sheet will be selected.
[Cut] Moves the right-clicked item to the copy buffer.
[Copy] Copies the right-clicked item to the copy buffer.
[Paste] Pastes the item from the copy buffer to the right-clicked location.
[Insert]
Inserts a line in the list.
Insertion is not possible if the item is at number 1000 in the list. If inserting multiple rows
that would exceed 1000 items in the list, items are inserted up to number 1000 in the list.
[Delete] Deletes the right-clicked item.
[Swap]
Swaps the right-clicked item.
Use [Swap][Source] to select the swap-source item, and use [Swap][Destination] to
select the swap-destination item. You can also select a swap-destination where there is
no item.
Add to Next
Available Number
Register in the earliest unused number.
Add to end Register after the last-registered parameter.