User Manual

11
Updating the Dante firmware
Described below are the procedures to update the Dante module firmware integrated in the Rio unit.
For details of the Dante Firmware Update Manager, refer to “AUD-MAN-Firmware Update Manager" stored in the
compressed file folder.
1. Connect the Dante [PRIMARY] connector on the rear panel of the Rio unit to the Ethernet connector
on the computer using an Ethernet cable.
Be sure to directly connect the computer and the Rio unit, and do not connect any other Dante device
to the computer.
2. Pull the dip switches 4 and 8 on the Rio unit front panel down (ON) with the other switches remaining
in their up positions (OFF).
3. Turn on the power to the Rio.
4. Select [Start][All programs][Audinate][Dante Firmware Update Manager][Dante Firmware
Update Manager ] , then right-click and select Run as Administrator.
The Dante Firmware Update Manager will start up.
Check that the version number is 1.3.2 or higher from the title bar.
The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
5. If you see the interface selection screen, select the interface card to connect the Dante device.
6. Click [Update Dante Firmware].