User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Appendices
Reference Manual
273
Electrical characteristics
All faders are nominal when measured. Output impedance of signal generator:150ohms
■ Frequency Response. Fs= 44.1 kHz or 48 kHz @20 Hz–20 kHz, referenced
to the nominal output level @1 kHz
■ Gain Error. Fs= 44.1 kHz or 48 kHz @1 kHz
■ Total Harmonic Distortion. Fs= 44.1 kHz or 48 kHz
* Total Harmonic Distortion is measured with a 18 dB/octave filter @80 kHz
■ Hum & Noise. Fs= 44.1 kHz or 48 kHz, EIN= Equivalent Input Noise
*Hum & Noise are measured with A-weight filter.
■ Dynamic Range. Fs= 44.1 kHz or 48 kHz
* Dynamic Range are measured with A-weight filter.
■ Sampling Frequency
Input Output RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8
OMNI OUT 1-8 600 Ω
GAIN: +66dB
–1.5 0.0 0.5
dB
PHONES 8 Ω –3.0 0.0 0.5
Input Output RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600 Ω
Input level : –62 dBu , GAIN : +66 dB
Output level +4.0 dBu (Typ.)
–2.0 0 2.0
dB
Input level : +10 dBu , GAIN : –6 dB
Output level +4.0 dBu (Typ.)
Internal OSC
OMNI OUT 1-8 600 Ω
Full scale output, Output level :
+24.0 dBu (Typ.)
–0.5 0 0.5
PHONES 8 Ω
–30 dBFs, phones level control : max.
Output level 0 dBu (Typ.)
–0.5 0 0.5
Input Output RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600 Ω
+4 dBu @20 Hz–20 kHz, GAIN: +66dB 0.1
%
+4 dBu @20 Hz–20 kHz, GAIN: –6dB 0.05
Internal OSC
OMNI OUT 1-8 600 Ω Full Scale Output @1 kHz 0.02
PHONES 8 Ω
Full Scale Output @1 kHz, PHONES Level
Control: Max.
0.2
Input Output RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600 Ω
Rs= 150 Ω, GAIN: +66dB
Master fader at nominal level and one
Ch fader at nominal level.
–128
EIN
dBu
–62
Rs= 150 Ω, GAIN: –6dB
Master fader at nominal level and one
Ch fader at nominal level.
–84 –79
All INPUTs OMNI OUT 1-8 600 Ω
Rs= 150 Ω, GAIN: –6dB
Master fader at nominal level and all
OMNI IN 1-8 in faders at nominal level.
–70
— OMNI OUT 1-8 600 Ω Residual Output Noise, ST Master Off –88
—PHONES 8 Ω
Residual Output Noise, PHONES Level
Control Min.
–88
Input Output RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600 Ω AD + DA, GAIN: –6dB 108 dB
— OMNI OUT 1-8 600 Ω DA Converter 112 dB
Parameter Conditions Min. Typ. Max. Unit
External Clock
Frequency
Range
Fs= 44.1 kHz
Fs= 45.9375 kHz (44.1 kHz +4.1667%)
Fs= 44.1441 kHz (44.1 kHz +0.1%)
Fs= 44.0559 kHz (44.1 kHz –0.1%)
Fs= 42.336 kHz (44.1 kHz –4.0%)
–200 +200 ppm
Fs= 48 kHz
Fs= 50 kHz (48 kHz +4.1667%)
Fs= 48.048 kHz (48 kHz +0.1%)
Fs= 47.952 kHz (48 kHz –0.1%)
Fs= 46.080 kHz (48 kHz –4.0%)
Jitter of PLL
DIGITAL IN Fs= 44.1 kHz
DIGITAL IN Fs= 48 kHz
10 ns
Internal Clock
Frequency
Word Clock : Int 44.1 kHz 44.1
kHz
Word Clock : Int 48 kHz 48
Accuracy
Word Clock : Int 44.1 kHz
–50 +50 ppm
Word Clock : Int 48 kHz
Jitter
Word Clock : Int 44.1 kHz 4.429
ns
Word Clock : Int 48 kHz 4.069