User Manual

22
*Notes
1) The HA setting of the M7CL-32/48 internal INPUT connector and the HA setting of the SB168-ES
that is connected to the M7CL-48ES are converted to the HA setting of the Rio3224-D/Rio1608-D
that is controlled by the CL/QL. In addition, the HA setting of the M7CL-32/48 internal ST IN
connector and the HA setting of the M7CL-48ES OMNI IN connector are converted to the HA
setting of the CL/QL internal OMNI IN connector.
2) The CL/QL has a Digital Gain setting in addition to the Attenuator setting. If the M7CL Attenuator
is set to 0 dB or higher, it is converted to a Digital Gain on the CL/QL. Furthermore, in the case of
conversion from CL/QL to M7CL, the sum of the CL/QL Attenuator and Digital Gain settings are
converted to the M7CL attenuator setting. When option 4 is ticked, the M7CL Attenuator settings
are converted to CL/QL Digital Gain settings in place of CL/QL Attenuator settings, even when the
M7CL Attenuator is less than 0 dB.
3) Key in source is reproduced according to the rules in the following table.
Dynamics Keyin Source –Input Channel
M7CL
Self Pre EQ
Self Post EQ
Mix 13-16
Self Post EQ
Nearby Ch
CL/QL
Self Pre EQ
Self Post EQ
Self Post EQ
Mix 21-24
Nearby Ch
Dynamics Keyin Source -Mix Channel
M7CL
Self Pre EQ
Self Post EQ
Mix 13-16
Self Pre EQ
Nearby Ch
CL/QL
Self Pre EQ
Self Post EQ
Self Pre EQ
Mix 21-24
Nearby Ch
Dynamics Keyin Source -Matrix Channel
M7CL
Self Pre EQ
Self Post EQ
Mix 13-16
Self Pre EQ
Matrix 1-8
CL/QL
Self Pre EQ
Self Post EQ
Self Pre EQ
Mix 21-24
Matrix 1-8
Dynamics Keyin Source -Stereo Channel
M7CL
Self Pre EQ
Self Post EQ
Mix 13-16
Self Pre EQ
Stereo L/R
Mono
CL/QL
Self Pre EQ
Self Post EQ
Self Pre EQ
Mix 21-24
Stereo L/R
Mono
4) Because the M7CL Attenuator range is from -96.0 dB to +24.0 dB and the CL/QL range is from -
96.0 dB to 0.0 dB, in the case of conversion from M7CL to CL/QL, limits may be placed on the
settings.
5) In the case of conversion from CL/QL to M7CL, the Effect units that are mounted to CL/QL Effect
Rack 1-4 are converted to blank states in M7CL GEQ/Effect Rack 1-4.
6) The M.Band Dyna. and M.Band Comp parameters between M7CL and CL/QL are different in their
types and ranges, so the settings are adjusted appropriately and converted.
M.Band Dyna. / M.Band Comp
LOW/MID/Hi. GAIN
TOTAL
EXP.RAT
MAKE UP
M7CL
-96.0dB - +12.0dB
n/a
1:1 - ∞:1
n/a
CL/QL
-12.0dB - +12.0dB
0dB
1:1 - 5:1
ON
The RATIO, ATTACK, RELEASE, KNEE, and BYPASS parameters of M.Band Comp were shared
among all bands on M7CL, but the parameters can be set separately for each band on CL/QL. Due to
this difference, these parameters are converted as indicated in the following figure.
- Conversion from M7CL to CL/QL:
The shared parameter settings on M7CL
are copied to the parameter settings of
each band on CL/QL.
LOW
RATIO
MID
RATIO
HI.
RATIO
ATTACK
RELEASE
KNEE
BYPASS
RATIO
ATTACK
RELEASE
KNEE
BYPASS
Copy
Copy
Copy
M7CL
CL/QL