User Manual

Display Operations
Owner’s Manual
24
Other functions
Initializing to the factory-set state
If you turn on the power while holding down both the (DEC) button and (INC) button, you can enter a mode that
returns this unit’s settings to their factory-set state. This is the same as if you use the SETUP menu to select INITIALIZE
→ FACTORY PRESET.
Initializing the HA parameters
If you turn on the power while holding down only the (DEC) button, you will enter a mode that returns the HA
parameter values to their factory-set state.
is is the same as if you use the SETUP menu to select INITIALIZE → HA PARAMETERS.
Initializing the Dante parameters
If you turn on the power while holding down only the (INC) button, you will enter a mode that returns the Dante
parameter values to their factory-set state. is is the same as if you use the SETUP menu to select INITIALIZE →
DANTE SETTINGS.
Factory-set initial values
The following table shows the factory-set initial values.
*1 The default setting of the Sample Rate is 96 kHz. Please be careful when using Rio-D2 in combination with devices which do not
support 96 kHz (such as CL or QL series).
*2 nnnnnn is the lowest six digits of the Dante Primary MAC Address.
Panel lock
While this unit is operating, you can put it in the panel lock state by simultaneously holding down the (DEC) button,
(INC) button, and the encoder with switch for approximately three seconds. This state is maintained even if the unit
is power-cycled. To defeat the panel lock state, simultaneously hold down the (DEC) button, (INC) button, and the
encoder with switch once again for approximately three seconds.
Brightness adjustment
While this unit is operating, simultaneously hold down the (DEC) button and (INC) button for at least 1.5 seconds,
and turn the encoder with switch to adjust the brightness of the display (BRIGHTNESS).
Parameter Initial value
SETUP UNIT ID Y001
START UP MODE REFRESH
SECONDARY PORT DAISY CHAIN
FAN SPEED LOW
NETWORK MODE AUTO
IP ADDRESS (determined by DHCP or link local)
SUBNET MASK (determined by DHCP or link local)
DEFAULT GW (determined by DHCP or link local)
DIMMER 3 min
ERROR MESSAGE LIGHT OFF
BRIGHTNESS 70%
HA Parameters HA GAIN –6 dB
+48V Off
HPF Off, 80.0 Hz
GAIN COMPENSATION Off, –6 dB
DANTE Settings Sample Rate 96 kHz (follower), Pull-up/down = None *1
Latency 1.0 ms
Encoding PCM 24 bit
Dante Redundancy Switched (depends on the setting of SETUP SECONDARY PORT)
IP Address Auto
Device Label Y001-Yamaha-Rio3224-D2-nnnnnn *2
Y001-Yamaha-Rio1608-D2-nnnnnn *2
Channel Label <channel number>
AES67 Mode Disabled
Device Lock Unlock