User Manual

Effects Parameters
20 RIVAGE PM series Data List
Buss Comp369
This compressor emulates a standard bus compressor that has been used in recording studios and
broadcasting stations.
MBC4
This four-band compressor offers intuitive operability.
Parameter Range Description
INPUT ADJUST –15.0 to +15.0 dB
Adjusts the input gain. However, the output gain changes
inversely in tandem with the level of this parameter so that the
volume remains the same as the pass-through volume. For
example if INPUT ADJUST is +5 dB, the input gain is +5 dB and
the output gain is –5 dB.
LINK ON, OFF Turns the stereo link on/off (only for stereo).
METER IN, GR, OUT Selects the signal source of the meter (only for stereo).
VU IN, OUT Selects the signal source for the VU meter (only for dual).
COMP IN ON, OFF Turns the compressor on/off.
COMP RATIO 1.5:1, 2:1, 3:1, 4:1, 6:1 Compressor ratio
COMP GAIN 0.0 to +20.0 dB Makeup gain of the compressor
COMP RECOVERY
100 ms, 400 ms, 800 ms,
1500 ms, a1, a2
Release time of the compressor. For a1 (auto 1) and a2 (auto 2),
the release time changes automatically.
a1: automatically changes in the range of 100 ms to 2sec.
a2: automatically changes in the range of 50 ms to 5 sec.
COMP THRESHOLD –40 to –5 dBFS Threshold of the compressor
LIMIT IN ON, OFF Turns the limiter on/off.
LIMIT ATTACK FAST, SLOW
Attack time of the limiter
FAST: 2 ms, SLOW: 4 ms
LIMIT RECOVERY
50 ms, 100 ms, 200 ms,
800 ms, a1, a2
Release time of the limiter. For a1 (auto 1) and a2 (auto 2), the
release time changes automatically.
a1: automatically changes in the range of 100 ms to 2sec.
a2: automatically changes in the range of 50 ms to 5 sec.
LIMIT THRESHOLD –16 to –5 dBFS Threshold of the limiter
Parameter Range Description
LOW CROSSOVER 20 to 500 Hz
Crossover frequency between the low and low-mid
frequency ranges
MID CROSSOVER 80 to 10 kHz
Crossover frequency between the low-mid and high-mid
frequency ranges
HIGH CROSSOVER 1k to 15 kHz
Crossover frequency between the high-mid and high
frequency ranges
LOW GAIN –18.0 dB to 12.0 dB Output gain of the low frequency range
LOW THRESHOLD –80.0 dB to 0.0 dB Threshold of the low frequency range
LOW RATIO 1.0:1 to 20.0:1 Compression ratio of the low frequency range
LOW ATTACK 0.1 to 120 ms Attack time of the low frequency range
LOW RELEASE 5 to 1000 ms Release time of the low frequency range
LOW COMP IN ON, OFF Turns the low-range compressor on/off.
LOW CUE ON ON, OFF
Turn on this parameter to cue-monitor the output of the
low frequency range.
LOW MID GAIN 18.0 dB to 12.0 dB Output gain of the low-mid frequency range
LOW MID THRESHOLD –80.0 dB to 0.0 dB Threshold of the low-mid frequency range
LOW MID RATIO 1.0:1 to 20.0:1 Compression ratio of the low-mid frequency range
LOW MID ATTACK 0.1 to 120 ms Attack time of the low-mid frequency range
LOW MID RELEASE 5 to 1000 ms Release time of the low-mid frequency range
LOW MID COMP IN ON, OFF Turns the low-mid range compressor on/off.
LOW MID CUE ON ON, OFF
Turn on this parameter to cue-monitor the output of the
low-mid frequency range.
HIGH MID GAIN –18.0 dB to 12.0 dB Output gain of the high-mid frequency range
HIGH MID THRESHOLD –80.0 dB to 0.0 dB Threshold of the high-mid frequency range
HIGH MID RATIO 1.0:1 to 20.0:1 Compression ratio of the high-mid frequency range
HIGH MID ATTACK 0.1 to 120 ms Attack time of the high-mid frequency range
HIGH MID RELEASE 5 to 1000 ms Release time of the high-mid frequency range
HIGH MID COMP IN ON, OFF Turns the high-mid range compressor on/off.
HIGH MID CUE ON ON, OFF
Turn on this parameter to cue-monitor the output of the
high-mid frequency range.
HIGH GAIN –18.0 dB to 12.0 dB Output gain of the high frequency range
HIGH THRESHOLD –80.0 dB to 0.0 dB Threshold of the high frequency range
HIGH RATIO 1.0:1 to 20.0:1 Compression ratio of the high frequency range
HIGH ATTACK 0.1 to 120 ms Attack time of the high frequency range
HIGH RELEASE 5 to 1000 ms Release time of the high frequency range
HIGH COMP IN ON, OFF Turns the high range compressor on/off.
HIGH CUE ON ON, OFF
Turn on this parameter to cue-monitor the output of the
high frequency range.
MASTER GAIN –18.0 dB to 12.0 dB Adjusts the gain of the final output signal.
KNEE HARD, 1, 2, 3, SOFT Adjusts the knee of the compressor.
FLAVOUR VCA, OPTO
Switches the type of the compressor between VCA
(accurate effects) and OPTO (natural effects).
HARMONICS ON, OFF
Switches on/off musical harmonics that emulate analog
circuitry.
LINK GAIN Adjusts the output gain for the four bands collectively.
LINK THRESHOLD Adjusts the threshold for the four bands collectively.
LINK RATIO
Adjusts the compression ratio for the four bands
collectively.
LINK ATTACK Adjusts the attack time for the four bands collectively.
LINK RELEASE Adjusts the release time for the four bands collectively.
Parameter Range Description