Crosstalk
@1 kHz Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* A 22 kHz, 30 dB/octave low pass filter is used to measure crosstalk.
Sampling frequency
Power requirements
Power cable length and temperature range
from/to to/from Conditions Min. Typ. Max. Unit
OMNI IN n OMNI IN (n-1) or (n+1) OMNI IN 1-8
adjacent inputs, GAIN: –6 dB
–100 dB
OMNI OUT n OMNI OUT (n-1) or (n+1) OMNI OUT 1-8, input to output –100 dB
Conditions Min. Typ. Max. Unit
External Clock Frequency Range Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz –1000 +1000 ppm
Jitter of PLL
*1
*1. Input clock jitter must be 1 ns or less.
DIGITAL IN Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz 10 ns
Internal clock Frequency Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
44.1
48
88.2
96
—kHz
Accuracy Word clock : int 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz –50 +50 ppm
Jitter
*2
*2. Measured at the WORD CLOCK OUT connector.
Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
——
4.5
4.1
2.3
2.1
ns
Conditions Min. Typ. Max. Unit
Power consumption 100–240 V 50/60 Hz
380 W
Heating value 100–240 V 50/60 Hz
330 kcal/h
Conditions Min. Typ. Max. Unit
Power cord length
250 cm
Temperature range Operating temperature range
0—40
°C
Storage temperature range
–20 60