User Manual

Analog Input Characteristics
*1 In these specifications, when dBu represents specific voltage values, 0dBu is referenced to 0.775 Vrms.
*2 1=GND, 2=HOT, 3=COLD
*3 CH1 – 16 AD converters are 24 bit linear.
*4 +48V DC (phantom power) is individually supplied to CH1 – 16 XLR connectors via each individual software controlled switch.
Dimensions (W x H x D) and Net Weight: 405 mm x 42 mm x 258 mm, 1.6 kg
Included Accessories: Owner’s Manual
RY16-DA
General Specifications
Measured with an RPio622
Frequency Response
Fs=44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz @ 20 Hz – 20 kHz, reference to the nominal output level (-20dBFS) @ 1 kHz
Total Harmonic Distortion
Fs=44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Total Harmonic Distortion is measured with an 18dB/octave filter @ 80 kHz.
Hum & Noise
Fs=44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Hum & Noise is measured with an IHF-A filter.
Dynamic Range
Fs=44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Dynamic range is measured with an IHF-A filter.
Input
Terminals
Gain
Actual Load
Impedance
For Use with
Nominal
Input Level
Connector
Balanced /
Unbalanced
Nominal
(-20dBFS)
Max
(0dBFS)
CH 1 – 16
+66dB
10 kΩ
50 – 600 Ω Mics &
600 Ω Lines
-62dBu (616 uV) -42dBu (6.16 mV)
XLR-3-31
type
*2
Balanced
-6dB +10dBu (2.45 V) +30dBu (24.5 V)
Input Output RL Conditions Min. Typ Max. Units
DIGITAL IN CH1 – 16 600 Ω -0.8 0.5 dB
Input Output RL Conditions Min. Typ Max. Units
DIGITAL IN CH1 – 16 600 Ω
Full scale output @ 1 kHz 0.006 %
+4dBu output @ 20 Hz – 20 kHz 0.02 %
Input Output RL Conditions Min. Typ Max. Units
DIGITAL IN CH1 – 16 600 Ω Digital data: OFF -92 dBu
Input Output RL Conditions Min. Typ Max. Units
DIGITAL IN CH1 – 16 600 Ω 116 dB