User Manual
Table Of Contents
- Cover
- What is Amp Editor?
- Special Notices
- Contents
- Preparing for operation
- An overview of Amp Editor
- Setup
- Basic operations in Amp Editor
- Main panel window
- Objects in the window and their function
- Menus in the main panel window
- Preferences
- Event Log
- Device Information
- Scene Manager
- Alert Setup
- Word Clock (TXn only)
- Speaker Processor Library Manager (TXn only)
- Clock
- Language (TXn only)
- GPI (ACD1 only)
- Utility
- IP Address
- IP Control Port No.
- Firmware Update (Updating the internal firmware)
- Scene Link Manager (for devices other than XMV)
- Network Setup
- Synchronization (Synchronization with devices)
- Custom Control Panel Manager
- System View Creator
- Speaker Processor Library Converter
- Tree View window
- Detail View window
- Device Properties window
- Signal Path View window (TXn only)
- Component editor (TXn only)
- Custom control panels
- Appendix
Chapter 10 Component editor (TXn only)
Amp Editor Owner’s Manual
176
I/O card
This lets you specify the input/output mode of a digital I/O card inserted in the slot. The parameters shown will
depend on the type of card. There is no editor for an AD card or DA card.
• For details on the MY16-CII card editor, refer to page177.
• The editor for an EtherSound card such as the MY16-ES64 cannot make EtherSound settings such as
routing. To make EtherSound settings, use the AuviTran Corporation’s AVS-ESMonitor software.
Input Format/Output Format
When operating at the high sampling rate (88.2/96 kHz), choose from the following to specify how signals
will be transmitted and received by the digital I/O card installed in the slot.
Double Speed
Use this setting when a device operating at the high sampling rate (88.2/96 kHz) is connected, and the
high sampling rate audio signals are being transmitted and received without change. (This setting can be
selected only for a digital I/O card that supports 96 kHz.)
Double Channel
Use this setting if high sampling rate (88.2/96 kHz) audio signals are being handled when a device operat-
ing at the conventional 44.1/48 kHz is connected. Two channels of signals at a sampling rate of half the
operating frequency (44.1/48 kHz) are combined, and sent or received as monaural signals at the high
sampling rate. (The number of usable channels will be halved.)
Parameter Range Function
q Input Format
DOUBLE SPEED,
DOUBLE CHANNEL,
SINGLE
Select the input mode used for the high sampling
rate (88.2/96 kHz).
This cannot be selected for a card that supports
only one format.
w Output Format
DOUBLE SPEED,
DOUBLE CHANNEL,
SINGLE
Select the output mode used for the high sampling
rate (88.2/96 kHz).
This cannot be selected for a card that supports
only one format.
e
Sampling Rate Con-
verter
(MY8-AE96S only)
On/Off Turns on the sampling rate converter.
DOUBLE FS On/Off
If this is on, the speed of the word clock from the MY
card will be doubled. This is shown only if this card
is specified as the word clock master.
NOTE
e
w
q