User Manual
Table Of Contents
- Cover
- What is Amp Editor?
- Special Notices
- Contents
- Preparing for operation
- An overview of Amp Editor
- Setup
- Basic operations in Amp Editor
- Main panel window
- Objects in the window and their function
- Menus in the main panel window
- Preferences
- Event Log
- Device Information
- Scene Manager
- Alert Setup
- Word Clock (TXn only)
- Speaker Processor Library Manager (TXn only)
- Clock
- Language (TXn only)
- GPI (ACD1 only)
- Utility
- IP Address
- IP Control Port No.
- Firmware Update (Updating the internal firmware)
- Scene Link Manager (for devices other than XMV)
- Network Setup
- Synchronization (Synchronization with devices)
- Custom Control Panel Manager
- System View Creator
- Speaker Processor Library Converter
- Tree View window
- Detail View window
- Device Properties window
- Signal Path View window (TXn only)
- Component editor (TXn only)
- Custom control panels
- Appendix
Chapter 3 Setup
Amp Editor Owner’s Manual
16
For the ACD1
1.
Power-on the ACD1.
After approximately ten seconds, the unit’s front panel display will show the HOME screen.
2. On the front panel of the unit, hold down the [BACK] button for one second or longer.
The Device ID setting screen will appear.
3. Use the [sINC/YES] or [tDEC/NO] button on the front panel of the unit to select the
Device ID. You can select a value in the range of 0–255.
If multiple ACD1 or TXn units are connected to a single network, set each unit to a different Device ID.
4. Press the front panel [NEXT] button.
The cursor moves to .
5. Press the front panel [sINC/YES] button.
The value you specified will be applied to the unit.
• If you move to a different screen without pressing the [sINC/YES] button, your change will not
be applied.
6. Repeat steps 1–5 to specify the Device ID for each connected ACD1 unit.
• You can also change the Device ID on Amp Editor’s [Change Device ID] dialog box (page 108)
after the devices are synchronized with Amp Editor.
For the XMV4140/XMV4280/XMV8140/XMV8280
1.
Power-off the XMV.
2. Use the DIP switches (1–3) to specify the upper digit, and use the rotary switch to specify
the lower digit to select the UNIT ID value from a maximum of 127 combinations in the
range of 01 through 7F (127).
• To change the switch settings, turn off the power to the unit. If you change the settings while the
power is on, the change will not be effective until you turn the unit off and then on.
• Do not use “00” as the UNIT ID.
For the XMV4140-D/XMV4280-D/XMV8140-D/XMV8280-D
1.
Power-off the XMV-D.
2. Use the rotary switch (HIGH) to specify the upper digit, and use the rotary switch (LOW)
to specify the lower digit to select the UNIT ID value from a maximum of 254 combina-
tions in the range of 01 through FE (254).
• Do not use “00” or “FF” as the UNIT ID.
• To change the switch settings, turn off the power to the unit. If you change the settings while the
power is on, the change will not be effective until you turn the unit off and then on.
NOTE
NOTE
NOTE
NOTE