User Manual

Troubleshooting
Owner’s Manual
17
Messages
Errors, warnings, and certain other types of information
are displayed via the Rio front panel indicators. Messages
are also displayed in the Dante Controller Error Status
field.
Each indicator lights or flashes as described below:
Error Messages
If one of the following errors has occurred, the device will
not operate. Until the error is resolved, the green SYSTEM
indicator will be turned off, and all indicators for all I/O
channels will continue to flash.
In addition, certain errors will cause the red SYSTEM
indicator to light or flash.
The following errors affect the settings or the hardware.
However, the device will still be usable. The green SYSTEM
indicator will light, and all indicators for all I/O channels
will work normally.
In addition, certain errors will cause the red SYSTEM
indicator to light or flash.
No call-out The indicator is off.
Light The indicator remains lit steadily.
Flash The indicator continues to flash.
Flash x2 The indicator flashes twice cyclically.
Flash x3 The indicator flashes three times cyclically.
SYSTEM
Indicators
Description Possible Solution
An internal error has
occurred.
The device has
failed. Contact your
Yamaha dealer for
repair.
Communication
cannot occur
because the MAC
address setting has
been corrupted.
UNIT ID is not
unique.
Set a unique UNIT
ID number within the
Dante network.
The device’s DIP
switches are not set
correctly.
Check the DIP switch
settings, and set
them correctly.
Flash x2
Flash x3
Light
Flash
SYSTEM
Indicators
Description Possible Solution
The number of Dante
transmit flows
exceeded the limit.
Reduce the number
of flows by, for
example, using
Dante Controller to
change some of the
transmit flows to
multicast.
The cooling fan has
stopped.
Check that nothing is
caught in the fan.
If the problem
persists, consult your
Yamaha dealer.
The internal memory
has been corrupted.
When using the unit
in [NORMAL] mode,
if the problem
persists even after
turning the power off
and on again,
consult your Yamaha
dealer.
You changed the
positions of the
device setting DIP
switches or rotary
switch, or changed
the Dante settings
from Dante
Controller.
Therefore, the
positions of the
device setting DIP
switches do not
match the actual
Dante settings.
If the Device Lock
setting was enabled
from Dante
Controller, disable
the setting, or check
the device setting
DIP switch positions,
and set them to
accommodate the
current situation.
FlashLight
Flash x2Light
Flash x3Light
LightLight